5. ADJUSTMENT

-23. Adjusting the sensor perceive plate position (Solenoid specifications)

3457Q

<KE-432B, 432C>

<BE-438B, 438C>

1.Remove the top cover (1) and the work clamp arm assembly (2).

Remove the top cover (1) and the button clamp assembly (2). [BE-438B, 438C]

3482Q

3484Q

3483Q

2.Remove the rubber cap (3) from the side of the arm. Approx. 5mm

3.Turn on the power switch.

4.While the X-SCALE indicator (4) on the operation panel is illuminated, hold down the TEST switch (5) and press the RESET switch (6) to activate input sensor check mode.

5.Press the SELECT switch (7) to illuminate the COUNTER indicator (8).

*The display (9) will show the work clamp signal status (ON, OFF).

6.Loosen the bolt (11) and move the sensor perceive plate (12) forward or back to adjust so that the work clamp signal is ON when the link C assembly (10) of the work clamp lifter mechanism is pushed so that the wiper is at the position shown in the illustration.

125

KE-430B, 430C series