5. ADJUSTMENT

-. Adjusting the work clamp lift amount (KE-430B, 430C, 431B, 431C, 433B)

The maximum work clamp lift amount is 17 mm from the top of the needle plate.

The lift amount for each model is adjusted as shown in the table at the time of shipment.

0151Q2566Q

17mm max.

 

 

KE-430B, 430C

 

KE-431B, 431C

 

KE-433B

 

 

 

 

 

 

 

 

 

 

 

spec.

-1, -5

 

-2

 

-7

-2, -3

-1

-2

-7

Lift amount

10+10 mm

 

14 +10 mm

 

9 +10 mm

10+10 mm

10+10 mm

14+10 mm

9 +10 mm

1.To adjust the work clamp lift amount, loosen the bolt (1) and move the presser arm lever plate (2) up or down.

2.Apply grease to the bottom of the presser plate (3) to the top of the presser arm lever plate (2) and to the sliding part of the work clamp (4) (grease is already applied at the time of shipment), and check that the movement becomes easier.

3.Check that there is a gap between the presser arm lever plate (2) and the presser plate (3) when the work clamp (4) is lowered.

*If movement is sluggish when the work clamp (4) is being raised and lowered, it may not be possible to increase the work clamp (4) lift amount.

*If the work clamp (4) cannot be raised or lowered, error code “E-61” or “E-63” will be displayed.

-. Adjusting the work clamp lift amount (KE-432B, 432C)

The maximum work clamp lift amount is 17 mm from the top of the needle plate when the machine is stopped. The lift amount is adjusted 13 +10 mm at the time of shipment.

17mm max.

2567Q

2568Q

While the machine is stopped, loosen the bolt (1) and move the presser roller attachment plate (2) vertically to adjust the lift amount.

*When making this adjustment, check to see if the work clamp will open. Also, readjust the closing distance of the work clamp according to the second procedure of “5-13. Work clamp closing-distance adjustment”.

*Loosen the nut (5) and turn the stop lever adjusting screw (6) to adjust the position of the stop lever (3) so that it does not touch the adjusting ring (4) when the work clamp is raised.

*If the work clamp cannot be raised or lowered, error code “E-61” or “E-63” will be displayed.