5. ADJUSTMENT

-30. Adjustment of air pressure (Pneumatic specifications)

 

Increase pressure

 

 

2621Q

1. Air pressure should be 0.5 Mpa.

 

 

 

 

 

The air pressure can be adjusted by pulling up

 

 

 

 

 

and turning the control knob (2) on the

 

 

Increase pressure

 

 

integrator (1).

 

 

 

After adjustment is complete, push the control

 

 

 

 

 

 

 

 

 

 

knob (2) downward to lock it.

 

 

 

 

 

 

 

 

 

 

2. Adjust the air pressure for the reversal cylinder

 

 

 

 

 

to stay within such a range that the presser

 

 

 

 

 

crank (4) rotates reversely when pressing the

 

 

 

 

 

sewing material with the pressure plate (3).

 

 

 

 

 

 

 

 

 

 

(Approx. 0.3 Mpa)

 

 

 

 

 

For adjustment, pull up and, turn the control

 

 

 

 

 

knob (6) on the air regulator (5).

 

 

 

 

 

After adjustment is complete, push the control

 

 

 

 

 

knob (6) downward to lock it.

 

 

 

 

 

 

 

 

 

 

3. If water stands in the bottle of the integrator (1),

 

 

 

 

 

turn the drain cock (7) in the direction indicated

 

 

 

 

 

by an arrow to drain the water.

 

 

 

 

 

 

2622Q

-31. Adjustment of inner clamping device

Adjustment of the positioning plates

Loosen the screws (2), and adjust the position of the positioning plate R (3) so that the label (1) can be evenly laid out between the front and back seams (A).

Next, loosen the screws (4), and adjust the position of the positioning plate L (5) so that the presser plate can be evenly laid out between the left and right seams (B).

2623Q

Adjustment of the presser crank horizontal position

Loosen the nut (3) and push in or pull out the adjusting bolt (4) so that the presser crank (2) can be horizontal when the reversal cylinder piston rod

(1) is moved to the left extreme.

2624Q

KE-430B, 430C series