8. ELECTRIC MECHANISM

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch

Possible

Units

Initial

Explanation

 

setting range

value

 

 

 

 

 

 

 

 

10

<KE-430*, 431*, 432*, 433B, 434*, 435*, 484C>

 

 

 

 

Changes the feed timing for the second stitch at the

 

memo-3A

1 - 20

×7.5°

 

sewing start.

 

 

<BE-438*>

 

 

 

 

 

 

 

 

 

1

Changes the feed timing for the second stitch at the

 

 

 

 

 

sewing start.

 

 

 

 

10

<KE-430*, 431*, 432*, 433B, 434*, 435*, 484C>

 

 

 

 

Changes the feed timing for the first stitch at the sewing

 

memo-3b

1 - 20

×7.5°

 

start.

 

1

<BE-438*>

 

 

 

 

 

 

 

 

Changes the feed timing for the first stitch at the sewing

 

 

 

 

 

start.

 

 

 

 

 

Sets the number of stitches for which the feed timing

 

memo-3c

0 - 99

Stitch

0

(memo-33 setting) is enabled.

 

0: Enabled for all stitches

 

 

 

 

 

1 - 99: Enabled for the specified number of stitches from

 

 

 

 

 

the sewing start

 

memo-3d

-

-

-

-

 

 

 

 

 

 

 

memo-3E

-

-

-

-

 

memo-3F

-

-

-

-

 

 

 

 

 

 

 

 

 

 

 

<KE-434*, 435*, 484C>

 

memo-40

1 - 5

-

4

Changes the test feeding speed (with no material).

 

 

 

 

 

1 (Fast) ←→ 5 (Slow)

 

 

 

 

 

<KE-435*>

 

memo-41

1 - 99

x10ms

10

Changes the standby time after the stepping foot is

 

 

 

 

 

raised.

 

 

 

 

 

<Solenoid specifications>

 

 

 

 

 

The work clamp operating mode can be changed.

 

 

0 - 10

-

0

(When set to “0”, the mode is selected according to the

 

 

settings for DIP switches A-1 and A-2.)

 

memo-42

 

 

 

 

 

 

 

Refer to “8-8. Setting the work clamp mode” for details

 

 

 

 

 

of the available modes.

 

 

0 - 13

-

0

<Pneumatic specifications>

 

 

5

<Inner clamping device specifications>

 

 

 

 

 

 

 

 

 

<KE-434*, 435*, 484C>

 

memo-43

1 - 3

-

3

Changes the allowable speed/sewing pitch.

 

 

 

 

 

1 (Fast) ←→ 3 (Standard)

 

 

 

 

 

<KE-434*, 435*, 484C>

 

 

 

 

0

Changes the path taken when moving from the machine

 

memo-44

0 - 3

-

home position to the start position.

 

 

0: Across inside of work clamp, 1: Top-left, 2:

 

 

 

 

 

Bottom-left, 3: Bottom-right

 

 

 

 

1

<Inner clamping device specifications>

 

 

 

 

1: Top-left, 2: Bottom-left, 3: Bottom-right

 

 

 

 

 

 

memo-45

-

-

-

-

 

-

 

memo-4c

 

 

 

 

 

memo-4d

0 - 10

x100ms

0

<KE-484C>

 

Changes the work clamp lift timing after sewing is

 

 

 

 

 

finished.

 

 

 

 

 

<KE-484C>

 

memo-4E

2 - 9

×7.5°

5

Tension release ON timing after thread trimming.

 

 

 

 

 

2 (Fast) ← 5 (Standard) →9 (Slow)

 

memo-4F

14 - 19

 

14

<KE-484C>

 

×7.5°

Thread trimming timing

 

 

 

 

 

14 (Standard) ↔ 19 (Slow)

KE-430B, 430C series

154