| 8. ELECTRIC MECHANISM |
|
|
|
|
|
|
|
|
|
|
|
|
| Switch | Possible | Units | Initial | Explanation |
| setting range | value | |||
|
|
|
| ||
|
|
|
| 10 | |
|
|
|
| Changes the feed timing for the second stitch at the | |
| 1 - 20 | ×7.5° |
| sewing start. | |
|
| ||||
|
|
|
|
| |
|
|
|
| 1 | Changes the feed timing for the second stitch at the |
|
|
|
|
| sewing start. |
|
|
|
| 10 | |
|
|
|
| Changes the feed timing for the first stitch at the sewing | |
| 1 - 20 | ×7.5° |
| start. | |
| 1 | ||||
|
|
|
| ||
|
|
|
| Changes the feed timing for the first stitch at the sewing | |
|
|
|
|
| start. |
|
|
|
|
| Sets the number of stitches for which the feed timing |
| 0 - 99 | Stitch | 0 | ||
| 0: Enabled for all stitches | ||||
|
|
|
|
| 1 - 99: Enabled for the specified number of stitches from |
|
|
|
|
| the sewing start |
| - | - | - | - | |
|
|
|
|
|
|
| - | - | - | - | |
| - | - | - | - | |
|
|
|
|
|
|
|
|
|
|
| |
| 1 - 5 | - | 4 | Changes the test feeding speed (with no material). | |
|
|
|
|
| 1 (Fast) ←→ 5 (Slow) |
|
|
|
|
| |
| 1 - 99 | x10ms | 10 | Changes the standby time after the stepping foot is | |
|
|
|
|
| raised. |
|
|
|
|
| <Solenoid specifications> |
|
|
|
|
| The work clamp operating mode can be changed. |
|
| 0 - 10 | - | 0 | (When set to “0”, the mode is selected according to the |
|
| settings for DIP switches | |||
|
|
|
| ||
|
|
|
| Refer to | |
|
|
|
|
| of the available modes. |
|
| 0 - 13 | - | 0 | <Pneumatic specifications> |
|
| 5 | <Inner clamping device specifications> | ||
|
|
|
| ||
|
|
|
|
| |
| 1 - 3 | - | 3 | Changes the allowable speed/sewing pitch. | |
|
|
|
|
| 1 (Fast) ←→ 3 (Standard) |
|
|
|
|
| |
|
|
|
| 0 | Changes the path taken when moving from the machine |
| 0 - 3 | - | home position to the start position. | ||
|
| 0: Across inside of work clamp, 1: | |||
|
|
|
|
| |
|
|
|
| 1 | <Inner clamping device specifications> |
|
|
|
| 1: | |
|
|
|
|
| |
| - | - | - | - | |
| - | ||||
|
|
|
|
| |
| 0 - 10 | x100ms | 0 | ||
| Changes the work clamp lift timing after sewing is | ||||
|
|
|
|
| finished. |
|
|
|
|
| |
| 2 - 9 | ×7.5° | 5 | Tension release ON timing after thread trimming. | |
|
|
|
|
| 2 (Fast) ← 5 (Standard) →9 (Slow) |
| 14 - 19 |
| 14 | ||
| ×7.5° | Thread trimming timing | |||
|
|
|
|
| 14 (Standard) ↔ 19 (Slow) |
154 |