3. DISASSEMBLY
Be careful not to drop these three bearing balls when removing the work clamp arm assembly.
3275Q
9.Rubber cap
10.Set screw [Loosen]
11.Tack width feed shaft
12.Screws [8 pcs]
13.Feed bracket guide plate [Pull upward]
14.Screw
15.Cover support stand
16.Feed bracket cover
17.Set screw [Loosen]
18.Tack length regulator block [Pull out]
19.Feed bracket guide shaft assy
20.Retainer assys [2 pcs]
21.Spacers [2 pcs]
22.Feed bracket assy
23.X feed cover
24.Y feed cover
25.Flat screws [2 pcs]
26.Screws [2 pcs]
27.Needle plate
1.Set screw
2.Needle
3.Needle bar thread guide
4.Bolts [2 pcs]
5.Work clamp arm assy
6.Work clamp felt
7.Bolts [2 pcs]
8.Feed plate
Remove the feed bracket guide plate as a single assembly with the feed bracket and other parts still assembled.
Be careful not to drop the two bearing balls when removing the feed bracket guide shaft assembly.
3276Q
26 |