8. ELECTRIC MECHANISM
Panel PCB
The panel PCB is fixed to the front panel of the operation panel. This PCB controls indications of the machine status and the input operation.
Operation panel
Panel PCB
Panel PCB
3584Q | 3585Q |
When replacing a fuse, follow the instructions indicated in “
When replacing a fuse, be sure to use the specified ones listed below.
No. | Part name | Part code | When a fuse has blown | |
|
|
| The feed mechanism and work clamp do not | |
1 | G fuse (5AFB) | operate. | ||
(quick melting type, | Error | |||
|
| |||
|
|
| 436C) | |
| G fuse (7AFB) |
| The machine motor does not turn. | |
2 | Error | |||
(quick melting type, | ||||
|
| 436C) | ||
|
|
| ||
3 | Fuse 6A | The power indicator is not illuminated, and | ||
(glass tube fuse, | nothing operates. | |||
|
| |||
4 | Fuse 6A | The power indicator is not illuminated, and | ||
(glass tube fuse, | nothing operates. | |||
|
|
Fuse
No.1
Fuse
No.3Fuse
No.2
Fuse
No.4
Main circuit board mounting side | Front panel |
3586Q | 3587Q |
139 |