5. ADJUSTMENT

[Pneumatic type]

3653Q

3462Q

 

 

 

 

 

 

Needle point

Approx.

30mm

3461Q

2579Q

1.While the sewing machine is stopped, loosen the set screw (3) and move the thread wiper arm assembly (4) up or down to adjust so that the clearance between the tip of the needle and the top of the wiper is 2 ± 0.5 mm when the thread wiper connecting rod assembly (1) is pushed up and the thread wiper (2) has passed below the needle.

*This adjustment should be made while the sewing machine is stopped. Be careful not to turn the machine pulley, otherwise the tip of the needle will move.

2.Loosen the two bolts (5) and move the wiper solenoid cover (6) up or down so that the thread wiper is approximately 30 mm from the needle when it is at the standby position.

[Stepping foot specifications]

2725Q

2727Q

 

 

 

 

 

 

 

 

 

Needle plate

3463Q

2726Q

1.While the sewing machine is stopped, loosen the set screw (3) and move the thread wiper arm assembly (4) up or down to adjust so that the clearance between the needle plate and the bottom of the wiper is 15–16 mm when the thread wiper connecting rod assembly (1) is pushed up and the thread wiper (2) has passed below the needle.

2.Loosen the two bolts (5) and move the solenoid cover (6) up or down so that the thread wiper is approximately 35 mm from the needle when it is at the standby position.

KE-430B, 430C series

112