8. ELECTRIC MECHANISM

-11. Clearing all memory settings

If the sewing machine stops operating normally, the cause may be that an incorrect memory setting may have been made by means of the memory switch, for instance. In such cases, carry out the following procedure to clear the memory, and also check the DIP switch settings.

3621Q

[KE-436B, 436C]

3622Q

[KE-430*, 431*, 432*, 433B, 434*, 435*, 484C, BE-438B]

While pressing the RESET switch (1), turn on the power. This will clear all of the memory setting.

[KE-436B, 436C]

While pressing the R/W switch (1), turn on the power. This will clear all of the memory setting.

Note:

This operation causes memory switches to be returned to their initial settings, and user program settings to be cleared.

If the optional emergency stop switch has been installed, you should reset memory switch No. 10 to ON.

KE-430B, 430C series

164