5. ADJUSTMENT

[KE-484C]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3206Q

 

 

 

 

3207Q

 

 

 

 

 

Loosen the nut (2) and move the connecting rod lever (3) to the left or right to adjust so that the V section A is aligned with the index mark B on the needle plate when the sewing machine in the stopped position and the movable knife (1) is pushed to the machine pulley side so that there is no play.

[KE-430B series]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3505Q

 

3468Q

 

 

 

 

 

Loosen the nut (2) and move the connecting rod lever (3) to the left or right to adjust so that the V section A is aligned with the index mark B on the needle plate when the sewing machine in the stopped position and the movable knife (1) is pushed to the machine pulley side so that there is no play.

117