8. ELECTRIC MECHANISM

-10. Checking the input voltage

3619Q

[KE-436B, 436C]

3620Q

1.Turn on the power switch.

2.Press the SELECT switch (1) until the Y-SCALE indicator (2) illuminates. [KE-436B, 436C]

Press the menu switch (1) until the X-SCALE indicator (2) illuminates.

3.While pressing the TEST switch (3), press the RESET switch (4).

[KE-436B, 436C]

While pressing the TEST switch (3), press the R/W switch (4).

4.If the input voltage is normal, the input voltage conditions will be shown in the display window (5) as indicated in the table above.

Specifications

Display

Notes

 

 

 

200V

[090 - 110]

 

 

 

“100” is displayed when the input voltage is 200 V.

220V

[100 - 120]

 

 

 

230V

[105 - 125]

 

 

 

 

100V

 

“110” is displayed when the input voltage is

380V

 

[100 - 120]

100V (for 100-V specs.), 380V (for 380-V specs.),

400V

 

400V (for 400-V specs.) or 415V (for 415-V specs.).

415V

 

 

 

 

 

 

5. Press the TEST switch (3) again to return the display to the normal condition.

163