8. ELECTRIC MECHANISM
Code |
|
|
| Cause |
|
|
|
|
|
|
| Remedy |
|
|
|
|
|
|
Stitch pattern data overlaps the sewing area | Press the RESET switch, and then reset the | |||||||||||||||||
memory switches “30” and | “31” or enlargement | |||||||||||||||||
| when area limiting is active. |
|
| ratio. |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| The data format of the user program (% or | After changing the setting of DIP switch | ||||||||||||||||
mm) does not match the setting of DIP | all memory settings. (Refer to | |||||||||||||||||
| switch |
|
|
|
|
| memory settings”.) |
|
|
|
|
|
|
| ||||
Length of a stitch exceeds 10 mm. |
| Press | the |
| RESET | switch, | and | then | set | the | ||||||||
| enlargement ratio again. |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Abnormality in the sewing data. |
|
| If programming a new sewing | data, | repeat | the | ||||||||||||
|
| procedure from the beginning. |
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Invalid program number specified. |
| Press | the | RESET switch and | specify | a | correct | |||||||||||
| number. |
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Needle bar does not stop when the needle is | Turn the pulley to align the index mark with the | |||||||||||||||||
needle up stop position. (Refer to | ||||||||||||||||||
| raised. |
|
|
|
|
| the needle up stop position”.) |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Presser has not been lowered. |
|
| Refer to “6. Troubleshooting”. |
|
|
|
|
|
| |||||||||
Presser cannot be raised. |
|
|
|
|
|
|
|
|
| |||||||||
|
|
| Turn off the power and check the connection of | |||||||||||||||
Presser is not raised. |
|
|
| |||||||||||||||
|
|
| presser sensor connector P1. |
|
|
|
|
|
| |||||||||
Presser cannot be lowered. |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Work | clamp | closed sensor stays on, | or | Refer to “6. Troubleshooting”. |
|
|
|
|
|
| ||||||||
sensor is incorrectly connected. |
|
| Turn off the power and check the connection of | |||||||||||||||
|
|
| ||||||||||||||||
Work clamp does not close. |
|
| work clamp closed sensor connector P1. |
|
|
| ||||||||||||
Thread trimmer cylinder does not operate. |
| Turn off the power and check the cylinder. |
|
| ||||||||||||||
Thread wiper cylinder does not operate. |
| Turn | off the | power, | and then | check if thread is | ||||||||||||
| ||||||||||||||||||
| tangled in the thread wiper. |
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
Cooling fan does not operate. |
|
| Turn off the power, and then check if the cooling fan | |||||||||||||||
|
| is blocked with scraps of thread. |
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
Motor PROM is not correctly inserted. |
| Turn off the power and check. |
|
|
|
|
|
| ||||||||||
Foot switch was depressed when the power | Turn off the power and check. |
|
|
|
|
|
| |||||||||||
| was turned on. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
An operation | panel switch was | depressed | Turn off the power and check the operation panel. | |||||||||||||||
when the power was turned on. |
|
| Check that all panel cords are normal. |
|
|
| ||||||||||||
|
|
|
|
|
| |||||||||||||
| Abnormal drop in power supply voltage, or | Turn off the power and check the input voltage. |
| |||||||||||||||
After turning off the power, wait 3 seconds or more | ||||||||||||||||||
power was turned on again immediately after | before turning it on again. (Refer to | |||||||||||||||||
| it was turned off. |
|
|
|
| |||||||||||||
|
|
|
|
| the input voltage”.) |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Abnormal rise in power supply voltage. |
| Turn | off the | power | and check | the | input | voltage. | ||||||||||
| (Refer to |
| ||||||||||||||||
|
|
|
|
|
|
|
|
| ||||||||||
Home position cannot be detected | Turn | off the | power | and check | the | connection | of | |||||||||||
(malfunction | of | home position | sensor), | or | home position sensor connector P1. |
|
|
|
| |||||||||
| malfunction of power supply circuit board. |
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
You | tried to | change the | program number | Press the RESET switch. |
|
|
|
|
|
| ||||||||
when DIP switch |
| Set DIP switch | ||||||||||||||||
|
| the program number. |
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
No sewing data available. |
|
|
| Replace the PROM with one which contains sewing | ||||||||||||||
|
|
| data. |
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Heat | sink | of | control | circuit | board | is | Turn off the power and clean the air intake port of | |||||||||||
abnormally hot. |
|
|
|
| the box. |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
| Malfunction of EEPROM (malfunction of | Turn off the power, and turn it back on. If the error | ||||||||||||||||
continually | occurs, | contact | a | qualified | service | |||||||||||||
| main circuit board). |
|
|
| technician. |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
168 |