| 8. ELECTRIC MECHANISM | |
|
|
|
|
|
|
|
|
|
|
|
|
| Code |
| Cause | Remedy | |
| E.40 | Floppy disk is not inserted or operation panel | Insert a floppy disk. If floppy disk is already inserted, |
| |
| turn off the power and check the connections of |
| |||
|
| cable is not securely connected. | cords inside the operation panel. |
| |
| E.41 |
|
|
| |
| Invalid program No., or no data. | Change program No. |
| ||
| E.43 | Different floppy disk! | Use original floppy disk. |
| |
| E.4F | Error occurred during floppy disk data | Replace the floppy disk and repeat the operation. |
| |
|
| reading. |
|
|
|
| E.50 | Floppy disk is | Release |
| |
| E.51 | Insufficient available memory on floppy disk. | Use another floppy disk. |
| |
| E.52 | Can not format this floppy disk. | Change floppy disk. |
| |
| E.5F | Error occurred during data writing on floppy | Replace the floppy disk and repeat the operation. |
| |
|
| disk. |
|
|
|
| E.60 | Can not backup data. (Panel PCB) | Turn off power and then clear all of the memory |
| |
| setting. |
| |||
|
|
|
|
| |
| E.61 | Can not backup data. (Control PCB) | Turn off power and then clear all of the memory |
| |
| setting. |
| |||
| E.62 |
|
|
| |
| Operation panel error. | Turn off power and then on again. |
| ||
| E.63 | Combination of control PROM and operation | Turn off power and check it. |
| |
|
| panel PROM is invalid. |
|
| |
| E.80 | Upper thread | has broken. (Rotary type | Thread upper thread again. You can start sewing |
|
| sensor) |
| again. |
| |
|
|
|
| ||
| E.81 | Upper thread has broken. (Optical fiber type | Thread upper thread again. You can start sewing |
| |
| sensor) |
| again. |
| |
|
|
|
| ||
| E.90 | Power supply voltage is extremely low, or | Turn off power and check voltage. After turning off |
| |
| power was turned on again immediately after | the power, wait 30 seconds or more before turning it |
| ||
| E.91 | it was turned off. |
| on again. |
|
| Power supply voltage is extremely high. | Turn off power and check voltage. |
| ||
| E.A0 | Start switch was pressed when there was no | Read sewing data again. |
| |
|
| sewing available data. |
|
| |
| E.A1 | Can not detect home position. | Turn off power and, check |
| |
| connection of | home position sensor is |
| ||
|
| incorrect. |
| P1. |
|
|
|
|
|
| |
| E.c0 | Motor PROM is not correctly inserted. | Turn off power and check it. |
| |
| E.c1 | Cooling fan in control box does not operate. | Turn off power and check whether any thread |
| |
| scraps have built up. Check fan connector. |
| |||
| E.c2 |
|
|
| |
| Turn off power and clean air inlet port. |
| |||
| E.d0 | Air pressure has dropped. | Turn off power and check it. If drops in air pressure |
| |
| are not being detected, clear all memory settings to |
| |||
|
|
|
| set the |
|
| E.E0 | Control PROM is not correctly inserted. | Turn off power and check it. |
| |
| E.E1 | Main PCB detected communication error. | Turn off power and then on again. |
| |
| E.E2 | Panel PCB detected communication error. | Turn off power and then on again. |
| |
| E.E3 | Incorrect connection of cable between | Turn off power and check it. |
| |
|
| operation panel and control box. |
|
| |
|
| Solenoid or feed motor |
|
| |
| E.F0 | (malfunction of main circuit board) or power | Turn off power and check it. |
| |
|
| supply relay is not operating (malfunction of |
|
| |
|
| power supply circuit board). |
|
| |
| E.F1 | Incorrect connection of cable between power | Turn off power and check connector P20. |
| |
|
| supply PCB and main PCB. |
|
| |
| E.F2 | Overcurrent at power supply PCB. | Turn off power and check it. |
|
170 |