5. ADJUSTMENT

-14. Adjusting the position of the button holder (BE-438B, 438C)

1. Loosen the two hexagonal bolts (1) and adjust the button holder body (2) by moving it.

2. Check that the needle will go through the button hole with no contact. (Refer to “CHECKING THE SEWING PATTERN” in the Instruction Manual.)

2668Q

-15. Work clamp adjustment (KE-435B, 435C, 436B, 436C)

1. Turn the pulley by hand to set the work clamp (1) to its lowest point.

2. Loosen screw (2), set the bottom of the work clamp (1) lightly against the work piece, and then tighten screw (2).

Note:

If the work clamp is lowered too far, the work piece will shift when sewing. Also, if the work clamp is too high, skipped stitches may occur.

3. Turn the pulley by hand, and make sure the needle enters the center of the needle hole in the work clamp (1). If the needle is not aligned with the center of the needle hole, remove cap (3), loosen screw (4), and turn the work camp (presser bar) to adjust.

3563Q

109