Cabletron Ethernet Hub Alarms and Events
Table | Events and Alarms (Continued) |
|
|
|
|
| Event Message | Probable Cause Message |
|
|
|
| 00010613 | 00010613 |
| Error threshold exceeded. An | This trap will be generated when |
| error threshold, {v}% of good | packets of the selected error |
| packets in {v} seconds, has | type exceeds a threshold |
| exceeded on port {v} (Instance | percentage of the good packets |
| ID {v}) of board in slot {v} | for a particular interval for a |
| (Instance ID {v}) of {v} (name - | particular port. |
| {v}). |
|
|
|
|
| 00010614 | 00010614 |
| Collision threshold exceeded. | This trap will be generated when |
| Collisions exceeded {v}% of good | collisions exceed a threshold |
| packets in {v} seconds on port | percentage of the good packets |
| {v} (Instance ID {v}) of board | for a particular interval for a |
| in slot {v} (Instance ID {v}) of | particular port. |
| {v} (name - {v}). |
|
|
|
|
| 00010615 | 00010615 |
| Port type changed. Port {v} | A port has been changed from a |
| (Instance ID {v}) on board in | station port to a link port, or |
| slot {v} (Instance ID {v}) of | vice versa. |
| {v} (name - {v}) is now type {v} |
|
| (Instance ID {v}). |
|
|
|
|
| 00010616 | 00010616 |
| Address lock changed for {v} | The status of the address lock |
| (name - {v}). New lock status is | has been changed. |
| {v} (1 = Off / 2 = On). |
|
|
|
|
| 00010617 | 00010617 |
| Port security violation occurred | A source address other than |
| on port {v} (Instance ID {v}) on | those locked to a port has been |
| board in slot {v} (Instance ID | seen. |
| {v}) of {v} (name - {v}). |
|
| Violating address is {v}. |
|
|
|
|
| 00010618 | 00010618 |
| Port violation reset. Port {v} | Management intervention has |
| (Instance ID {v}) on board in | reset a port after a violation |
| slot {v} (Instance ID {v}) of | has occurred. |
| {v} (name - {v}) has been reset. |
|
|
|
|
| 00010619 | 00010619 |
| Environment Temperature Warm | This device detects that the |
| detected by {v} (name - {v}). | temperature within the device |
|
| has reached a WARM condition. |
|
|
|
Event and Alarm Messages | Cabletron Ethernet Hubs |
Management Module Guide |