9030367 E7 Configuration Views
4-13
Configuration View Description
Redundancy View
Panels at the bottom of the Redundancy Information View provide additional
information. For the IRM2, MRXI, and MiniMMAC, the panels are Board
Member, Port Member, and Redundancy Table. For the IRM3, there are two
Redundancy Table panels. Double-clicking on any of the entries in the Polled
Address list of the Redundancy Table for the IRM2, MRXI, or MiniMMAC
opens the Address Display View. The Address Display View has two fields:
Polled Address, which is the MAC address, and Instance, which is the
board number and port number associated with the address. For example, 1.1
is board 1, port 1. The IRM3 has no Address Display View.
The Redundancy Information View also provides the following two buttons:
The Address Delete View button displays the Address Delete View. This
view contains the Redundancy Table and a field. Table 4-4 provides the
information contained in the view.
The IRM2, MRXI, and MiniMMAC Address Delete Views allow you to double-
click on the Polled Addresses in the Redundancy Table to access an Address
Display View. The Address Display View has two fields: Polled Address,
which is the MAC address, and Instance, which is the board number and port
number associated with the address. For example, 1.1 is board 1, port 1.
This button allows you to access the Circuit Reset View. This view allows you
to reset a single Redundancy circuit. Table 4-5 provides the information
contained in the view.
Address Delete View
Table 4-4. Address Delete View Fields
Field Definition
MAC Address Delete
(IRM2), MRXI,
MiniMMAC
Removes the Ethernet address from the polling list
for the indicated circuit. You enter a MAC address in
this field.
IP Address Delete
(IRM3)
Removes the IP address from the polling list for the
indicated circuit. You enter an IP address in this field.
Reset Circuit View
Table 4-5. Circuit Reset View Fields
Field Definition
Circuit Number The circuit number to be reset.