Cabletron Ethernet Hub Alarms and Events

Table 7-1.

Events and Alarms (Continued)

 

 

 

 

 

Event Message

Probable Cause Message

 

 

 

 

00010606

00010606

 

Source Address {v} (Instance ID

Not Applicable.

 

{v}) timeout detected by {v}

 

 

(name - {v}) on port {v}

 

 

(Instance ID {v}) of board in

 

 

slot {v} (Instance ID {v}).

 

 

 

 

 

00010607

00010607

 

Device configuration change

A MIM has been removed from this

 

reported by {v} (name - {v}).

MMAC.

 

Board in slot {I 1} (Instance ID

 

 

{0 2}) has been removed.

 

 

 

 

 

00010608

00010608

 

Device configuration change

Not Applicable.

 

reported by {v} (name - {v}).

 

 

Board type {I 3} has been

 

 

installed in slot {I 1}. Its new

 

 

instance ID is {0 2}.

 

 

 

 

 

00010609

00010609

 

Network configuration change

An active port in a redundant

 

reported by {v} (name - {v}).

circuit has failed polling. This

 

Port {v} (Instance ID {v}) on

indicates the activation of

 

board in slot {v} (Instance ID

redundancy.

 

{v}) has failed polling.

 

 

Redundancy activated for Circuit

 

 

{v} (Instance ID {v}).

 

 

 

 

 

0001060a

0001060a

 

Network configuration change

Not Applicable.

 

reported by {v} (Instance ID

 

 

{v}). Port {v} (Instnace ID {v})

 

 

on board in slot {v} (Instance

 

 

ID {v}), Circuit {v} (Instance

 

 

ID {v}) has been activated.

 

 

 

 

 

0001060b

0001060b

 

Redundancy diagnostics of {v}

During this MMAC’s periodic

 

(name - {v}) indicate port {v}

redundancy diagnostics, it was

 

(Instance ID {v}) on board in

found that a port in a redundant

 

slot {v} (Instance ID {v}),

cycle has failed. This does not

 

Circuit {v} (Instance ID {v})

indicate that redundancy has

 

has failed.

been activated, but it should be

 

 

fixed before it is needed.

 

 

 

Event and Alarm Messages

Cabletron Ethernet Hubs

7-4

Management Module Guide

Page 113
Image 113
Cabletron Systems Ethernet Hubs manual 00010606