Configuration View Description

Redundancy View

Error Source Table

The Configure Alarms View also displays an Error Source Table, which displays a series of buttons which allow you to select the types of errors that will cause alarms. Table 4-2provides the definitions of the errors contained in the Error Source Table.

Table 4-2.

Error Source Table Fields

 

 

 

 

Error

Definition

 

 

 

 

Align

Measures the number of misaligned frames detected by the

 

 

hub.

 

 

 

 

Runts

Measures the number of runt frames detected by the hub.

 

 

 

 

Giants

Measures the number of packets longer than 1,518 bytes

 

 

detected by the hub.

 

 

 

 

CRC

Measures the number of packets with bad Cyclic

 

 

Redundancy Checks (CRCs) detected.

 

 

 

 

OOW

Measures the number of Out-Of-Window (OOW) collisions

 

 

detected by the hub.

 

 

 

 

No_Resource

Measures the number of No_Resource errors detected by the

 

 

hub.

 

 

 

Redundancy View

You can access the Redundancy View by clicking on the Redundancy button in the Configuration View. This view is not available for the IRBM or the IRM hubs. The Redundancy View provides the following information:

Model Name

The user-defined or default name of the model.

Device Name

An ASCII name of the device that this agent manages.

Maximum Circuits

The maximum number of circuits.

Available Circuits

The number of available circuits. This field does not appear in the IRM3

Redundancy View.

Redundant Poll Interval

The number of seconds between polls for redundancy.

9030367 E7

Configuration Views

 

4-11

Page 68
Image 68
Cabletron Systems Ethernet Hubs manual Redundancy View