9030367 E7 Configuration Views
4-19
Configuration View Description
Bridge Configuration View
This button allows you to access the Setup Information View. Table 4-10
provides the information contained in the view.
Table 4-9. Additional Bridge Information View Fields
Field Definition
Model Name The user-defined name or default name of the model.
Bridge Priority The part of the bridge address that contains the identifier
used in the spanning tree for priority comparisons. The
allowed range is 0 through FFFF. The default is 8000.
Hold Time The minimum time period elapsing between the
transmission of configuration BPDUs through a given bridge
port.
Protocol Max Age The maximum age of received protocol information before it
is discarded.
Trap Type Obj ID Contains the object identifier of the first VarBinding in the
last trap generated by the bridge.
Bridge Setup Information
Table 4-10. Setup Information View Fields
Field Definition
Model Name The user-defined name or default of the model.
Bridge ID The unique identifier of the bridge. The first two bytes of the
identifier are the bridge priority and the last six bytes are the
Ethernet address.
Switch Settings The current switch settings read from the bridge hardware.
Number of
Restarts
The number of times the bridge has been powered up or
restarted.
Type of Filtering The type of filtering to be performed by the bridge. The
default is IEEE 802.1.
STA Protocol The spanning tree algorithm under which the bridge is
operating. Selections include: 802.1-compliant spanning tree
algorithm environment (802.1), DEC LAN Bridge 100
environment (DEC) and without spanning tree algorithm
enabled (None). The default is 802.1.