Configuration View Description

 

 

 

 

 

 

 

 

Bridge Configuration View

Table 4-9.

Additional Bridge Information View Fields

 

 

 

 

 

 

Field

 

Definition

 

 

 

 

 

 

 

Model Name

The user-defined name or default name of the model.

 

 

 

 

 

 

 

Bridge Priority

The part of the bridge address that contains the identifier

 

 

 

used in the spanning tree for priority comparisons. The

 

 

 

allowed range is 0 through FFFF. The default is 8000.

 

 

 

 

 

 

 

Hold Time

The minimum time period elapsing between the

 

 

 

transmission of configuration BPDUs through a given bridge

 

 

 

port.

 

 

 

 

 

 

 

Protocol Max Age

The maximum age of received protocol information before it

 

 

 

is discarded.

 

 

 

 

 

 

 

Trap Type Obj ID

Contains the object identifier of the first VarBinding in the

 

 

 

last trap generated by the bridge.

 

 

 

 

 

 

 

 

 

 

Bridge Setup Information

 

 

 

 

 

This button allows you to access the Setup Information View. Table 4-10

 

provides the information contained in the view.

Table 4-10.

Setup Information View Fields

 

 

 

 

 

Field

 

Definition

 

 

 

 

 

 

Model Name

The user-defined name or default of the model.

 

 

 

 

 

 

Bridge ID

The unique identifier of the bridge. The first two bytes of the

 

 

 

identifier are the bridge priority and the last six bytes are the

 

 

 

Ethernet address.

 

 

 

 

 

 

Switch Settings

The current switch settings read from the bridge hardware.

 

 

 

 

 

 

Number of

The number of times the bridge has been powered up or

 

 

Restarts

restarted.

 

 

 

 

 

 

Type of Filtering

The type of filtering to be performed by the bridge. The

 

 

 

default is IEEE 802.1.

 

 

 

 

 

 

STA Protocol

The spanning tree algorithm under which the bridge is

 

 

 

operating. Selections include: 802.1-compliant spanning tree

 

 

 

algorithm environment (802.1), DEC LAN Bridge 100

 

 

 

environment (DEC) and without spanning tree algorithm

 

 

 

enabled (None). The default is 802.1.

 

 

 

 

 

 

9030367 E7

Configuration Views

 

4-19

Page 76
Image 76
Cabletron Systems Ethernet Hubs manual Additional Bridge Information View Fields, Bridge Setup Information