Configuration View Description
Control View
Configuration Views Cabletron Ethernet Hubs
4-8 Management Module Guide
Network Address
The network IP address (e.g., 132.177.118.24). This field does not appear in
the IRM Control View.
This button allows you to reset all of the device’s counters to 0.
This button allows you to restart the device.
This button allows you to reset the redundancy for the entire hub. This button
is not available in the IRBM or the IRM Control Views.
This button causes the device and all devices connected to it to send Link-up
traps. This button is not available in the IRM, IRM3, or MRXI Control Views.
Source Address Age Time
The number of seconds that a source address is not detected before it is
removed from the source address table. This field does not appear in the IRM
or MRXI Control Views.
This button controls sending of source address related traps. Possible options
are TrapsOn and TrapsOff. This button is not available in the IRM or MRXI
Control Views.
This button indicates whether detection of source addresses on a port that are
not in the source address table will cause the port to be turned off. Possible
states are LockOff and LockOn. If a port is turned off, an event and alarm will
be generated to warn you of this condition. This button is not available in the
IRM or MRXI Control Views.
Counters
Restart Device
Device Redundancy
Device Discover
Source Address Traps
Source Address Lock