MIM Performance View

IRBM, IRM2, IRM3 and MiniMMAC Hubs

which allows you to set threshold alarms and enable them. Table 6-4displays the information contained in this view. The Configure Alarms View also displays an Error Source Table, which lets you select the types of errors that will cause alarms. Table 4-2,in the Configuration View chapter, provides the information contained in the Error Source Table.

Table 6-4.

MIM Configuration View Fields

 

 

 

 

Field

Description

 

 

 

 

MIM Name

The name of the module.

 

 

 

 

Serial Number

The serial number of the MIM device.

 

 

 

 

MIM Type

The type of module (i.e., IRM2).

 

 

 

 

Slot Number

The number of the hub slot that contains the

 

 

module.

 

 

 

 

Ports On Out Of

The number of operating ports on the device out of

 

 

the total number of ports.

 

 

 

Table 6-5.

IRM2, IRM3, IRBM, and MiniMMAC Configure Alarms View Fields

 

 

 

 

Field

Description

 

 

 

 

Model Name

The user-defined or default name of the module

 

 

model.

 

 

 

 

MIM Name

The name of the module device.

 

 

 

 

Slot Number

The number of the hub slot that contains the

 

 

module.

 

 

 

 

Traffic Alarms

Enables the sending of device-level traffic traps.

 

 

 

 

Traffic Threshold Alarm

Permits a port to be disabled on a traffic threshold

 

 

alarm.

 

 

 

 

Traffic Threshold

The threshold of packets within the Time Base that

 

 

will cause a traffic alarm.

 

 

 

 

Collisions Alarms

Enables the sending of device-level collision alarms.

 

 

 

 

Collisions Threshold Alarm

Permits a port to be disabled on a collision threshold

 

 

alarm.

 

 

 

 

Collisions Threshold

The threshold of collisions per good packet that will

 

 

generate an alarm. Values can be 1 to 15.

 

 

 

 

Error Alarms

Enables the sending of device-level error alarms.

 

 

 

 

Error Threshold Alarm

Permits a port to be disabled on an error threshold

 

 

alarm.

 

 

 

 

Error Threshold

The threshold of errors per good packet that will

 

 

generate an alarm.

 

 

 

9030367 E7

Performance Views

 

6-9

Page 98
Image 98
Cabletron Systems Ethernet Hubs manual MIM Configuration View Fields, Field Description