Chapter 3 Installing the Cisco Wide Area Application Engine

Installing the Cisco Wide Area Application Engine

To install the chassis in a two-post rack, follow these steps:

Step 1 Attach a bracket to one side of the chassis, aligning the front flange of the bracket with the hash mark on the side of the chassis. (See Figure 3-2.)

Figure 3-2 Installing the Chassis in the Rack

Rear

124555

Front

Step 2 Attach a second bracket to the opposite side of the chassis in the same manner.

Step 3 After you secure the brackets to the chassis, rack-mount the chassis by threading at least two screws through the bracket flanges on each side of the chassis into the corresponding holes in each side of the rack. You need two people to install the chassis in the rack—one person to hold the chassis and one person to secure it to the rack.

The inlet and exhaust ports for cooling air are located in the front and rear of the chassis, respectively; therefore, multiple chassis can be stacked with little or no vertical clearance.

Installing the Chassis in a Four-Post Rack

The four-post rack-mounting system does not require any tools for installation, unless you are shipping a device mounted in a rack. When you are shipping a device in a rack, you need a Phillips screwdriver. Figure 3-3shows the items that you need to install the chassis in a four-post rack. If any items are missing or damaged, contact your place of purchase.

 

Cisco Wide Area Application Engine 511 and 611 Hardware Installation Guide