Figure 4-10: Grounding the Unit (AC)

Chapter 4 Installation and Maintenance

Installing the SCE 2000 Platform

To connect the grounding cable to the chassis grounding connector on the SCE 2000, complete the following steps:

Step 1 From the enclosed Grounding kit, remove the necessary materials: the grounding cable (green and yellow colored cable) and pairs of hex nuts and spring washers.

Step 2 On the Rear panel of the SCE 2000, locate the chassis grounding connector (refer to the appropriate figure for an AC- or DC-powered SCE 2000 below).

Step 3 Attach the grounding cable (green and yellow colored cable), firmly fastening the (enclosed) hex nuts and spring washers with a #¼” hex wrench (refer to the appropriate figure for an AC- or DC-powered SCE 2000 below).

The other side of the grounding cable must be connected to the site equivalent of the AC earth.

Figure 4-10: Grounding the Unit (AC)