Configuring the NME-NAM-120S For Network Connectivity

SUMMARY STEPS

1.enable

2.configure terminal

3.ip cef

4.interface type slot/port or

interface type slot/wic-slot/port

5.analysis-module monitoring

6.Repeat Step 4 and Step 5 for each interface that you want the NAM to monitor.

7.end

8.show running-config

DETAILED STEPS

 

 

 

Command or Action

Purpose

 

 

 

 

 

 

Step 1

enable

Enables privileged EXEC mode.

 

 

 

 

 

Enter your password if prompted.

 

 

 

Example:

 

 

 

 

 

Router> enable

 

 

 

 

 

 

 

 

Step 2

configure terminal

Enters global configuration mode.

 

 

 

Example:

 

 

 

 

 

Router# configure terminal

 

 

 

 

 

 

 

 

Step 3

ip cef

Enables the Cisco Express Forwarding switching path.

 

 

 

Example:

 

 

 

 

 

Router(config)# ip cef

 

 

 

 

 

 

 

 

Step 4

interface type slot/port

Selects an interface for configuration.

 

 

 

or

 

 

 

 

 

interface type slot/wic-slot/port

 

 

 

 

 

Example:

 

 

 

 

 

Router(config)# interface serial 0/0

 

 

 

 

 

 

 

 

Step 5

analysis-module monitoring

Enables NAM packet monitoring on the interface.

 

 

 

Example:

 

 

 

 

 

Router(config-if)# analysis-module monitoring

 

 

 

 

 

 

 

 

Step 6

Repeat Step 4 and Step 5 for each interface that you

 

 

 

want the NAM to monitor through the internal NAM

 

 

 

 

 

interface.

 

 

 

 

 

 

 

 

 

 

 

 