1.Login as root to your KVM/net and execute the following commands.

[root@KVMNet root]#scp paul@192.168.51.242:/home/ paul/cyclades/zImage_kvm_200.bin /proc/flash/ zImage_kvm_200.bin

[root@KVMNet root]#scp paul@192.168.51.242:/home/ paul/cyclades/zImage_kvm_200.md5 /proc/flash/ zImage_kvm_200.md5

2.Execute the following command as “root” to generate the md5 checksum of the upgraded firmware file.

[root@KVMNet root]# md5sum /proc/flash/ zImage_kvm_200.bin

3.The following md5 file is generated and displayed.

77d44763e549064f42f7103768c5cad9 zImage_kvm_200.bin

4.Use the cat command to compare the displayed checksum with the checksum provided with the firmware.

[root@KVM/net flash]# cat zImage_kvm_200.md5

Note: The displayed checksum must be identical with the checksum provided with the firmware (*.md5 file). If the checksum is different, it means that a problem occurred during the download process, and the firmware may be damaged. In this case please check the steps you took during the upgrade process and try again.

Warning! Do not reboot the KVM/net until you have upgraded the firmware successfully.

5.If you would like to set the unit back to factory default, enter the following command. Assumption is that you are logged in as “root”.

438