Cypress CY7C67200 manual SPI Control Register 0xC0CA R/W, Strobe, Receive Bit Length

Models: CY7C67200

1 78
Download 78 pages 5 Kb
Page 55
Image 55
SPI Control Register [0xC0CA] [R/W]

CY7C67200

SPI Control Register [0xC0CA] [R/W]

Figure 62. SPI Control Register

Bit #

15

14

13

12

11

10

9

8

Field

SCK

FIFO

Byte

Full Duplex

SS

Read

Transmit

Receive

Strobe

Init

Mode

 

Manual

Enable

Ready

Data Ready

Read/Write

W

W

R/W

R/W

R/w

R/W

R

R

Default

0

0

0

0

0

0

0

1

 

 

 

 

 

 

 

 

 

Bit #

7

6

5

 

4

 

3

2

 

1

 

0

Field

Transmit

Receive

 

Transmit Bit Length

 

 

Receive Bit Length

 

Empty

Full

 

 

 

 

 

 

 

 

 

 

Read/Write

R

R

R/W

 

R/W

 

R/W

R/W

 

R/w

 

R/W

Default

1

0

0

 

0

 

0

0

 

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

Register Description

The SPI Control register controls the SPI port. Fields apply to both master and slave mode unless otherwise noted.

SCK Strobe (Bit 15)

The SCK Strobe bit starts the SCK strobe at the selected frequency and polarity (set in the SPI Configuration register), but not phase. This bit feature can only be enabled when in master mode and must be during a period of inactivity. This bit is self-clearing.

1:SCK Strobe Enable

0:No Function

FIFO Init (Bit 14)

The FIFO Init bit initializes the FIFO and clear the FIFO Error Status bit. This bit is self-clearing.

1:FIFO Init Enable

0:No Function

Byte Mode (Bit 13)

The Byte Mode bit selects between PIO (byte mode) and DMA (block mode) operation.

1:Set PIO (byte mode) operation

0:Set DMA (block mode) operation

Full Duplex (Bit 12)

The Full Duplex bit selects between full-duplex and half-duplex operation.

1:Enable full duplex. Full duplex is not allowed and will not set if the 3Wire Enable bit of the SPI Configuration register is set to ‘1’

0:Enable half-duplex operation

SSManual (Bit 11)

The SS Manual bit activates or deactivates SS if the SS Delay Select field of the SPI Control register is all zeros and is configured as master interface. This field only applies to master mode.

1:Activate SS, master drives SS line asserted LOW

0:Deactivate SS, master drives SS line deasserted HIGH

Read Enable (Bit 10)

The Read Enable bit initiates a read phase for a master mode transfer or set the slave to receive (in slave mode).

1:Initiates a read phase for a master transfer or sets a slave to receive. In master mode this bit is sticky and remains set until the read transfer begins.

0:Initiates the write phase for slave operation

Transmit Ready (Bit 9)

The Transmit Ready bit is a read-only bit that indicates if the transmit port is ready to empty and ready to be written.

1:Ready for data to be written to the port. The transmit FIFO is not full.

0:Not ready for data to be written to the port

Receive Data Ready (Bit 8)

The Receive Data Ready bit is a read-only bit that indicates if the receive port has data ready.

1:Receive port has data ready to read

0:Receive port does not have data ready

Transmit Empty (Bit 7)

The Transmit Empty bit is a read-only bit that indicates if the transmit FIFO is empty.

1:Transmit FIFO is empty

0:Transmit FIFO is not empty

Receive Full (Bit 6)

The Receive Full bit is a read-only bit that indicates if the receive FIFO is full.

1:Receive FIFO is full

0:Receive FIFO is not full

Transmit Bit Length (Bits [5:3])

The Transmit Bit Length field controls whether a full byte or partial byte is to be transmitted. If Transmit Bit Length is ‘000’, a full byte is transmitted. If Transmit Bit Length is ‘001’ to ‘111’, the value indicates the number of bits that will be transmitted.