CY7C67200

Table 41.DC Characteristics: Charge Pump (continued)

Parameter

Description

Conditions

Min.

Typ.

Max.

Unit

VA_SESS_VALID

A-Device Session Valid

 

0.8

 

2.0

V

VB_SESS_VALID

B-Device Session Valid

 

0.8

 

4.0

V

VA_SESS_END

B-Device Session End

 

0.2

 

0.8

V

E

Efficiency When Loaded

ILOAD = 8 mA, VCC = 3.3V

 

75

 

%

RPD

Data Line Pull Down

 

14.25

 

24.8

RA_BUS_IN

A-device VBUS Input Impedance

VBUS is not being driven

40

 

100

k

 

to GND

 

 

 

 

 

RB_SRP_UP

B-device VBUS SRP Pull Up

Pull-up voltage = 3.0V

281

 

 

RB_SRP_DWN

B-device VBUS SRP Pull Down

 

656

 

 

USB Transceiver

USB 2.0-compatible in full- and low-speed modes.

This product was tested as compliant to the USB-IF specification under the test identification number (TID) of 100390449 and is listed on the USB-IF’s integrators list.

AC Timing Characteristics

Reset Timing

tRESET

nRESET

nRD or nWRL or nWRH

tIOACT

Reset Timing

Parameter

Description

Min.

Typ.

Max.

Unit

tRESET

nRESET Pulse Width

16

 

 

clocks[9]

tIOACT

nRESET HIGH to nRD or nWRx Active

200

 

 

µs

Note

9. Clock is 12 MHz nominal.

Document #: 38-08014 Rev. *G

Page 67 of 78

[+] Feedback

Page 67
Image 67
Cypress CY7C67200 manual AC Timing Characteristics, Reset Timing