EAS Timeout

Specifies the amount of time that an EAS (Electronic Article Survellance) signal is held in its active state for a good read.

To set the EAS Timeout:

1.Scan the SWITCH bar code.

2.Scan the bar code, SET EAS TIMEOUT below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

3.Scan the appropriate digits from the keypad in Appendix C that represent the desired EAS Timeout duration. The selectable range is 0-255, which is the timeout in 10-millisecond increments. Pad all single and double digit numbers with leading zeroes to yield a three-digit entry (000-255).

Examples:

000 = EAS timeout disabled

001 = 10ms

005 = 50ms

040 = 400ms

250 = 2,500ms (2.5 seconds)

A setting of 0 (000) disables this feature.

NOTE

4.The scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned

SET EAS TIMEOUT

Product Reference Guide

6-45