The connector at the Remote Scale Display end is secured with a rubber

 

band during shipping to prevent damage to the “locking tabs” (see

 

Figure 2-14). After routing the cable, remove this rubber band before the

 

cable end connecting to the Remote Scale Display head. Failure to remove

NOTE

the band will keep the connector from latching properly when it is connected

to Remote Scale Display port.

 

Placing and Installing the Remote Scale Display(Short Pedestal Base ONLY)

1.Determine where you want to install the Remote Scale Display based on your counter design, the viewing angle and lighting con- siderations discussed previously. Reference Figure 2-13for the display’s physical dimensions.

2.Use the short pedestal base template provided in Figure 2-15to mark locations of the mounting screw and cable routing holes. The mounting screw holes are on 3 3/8” (8.57 cm) centers.

Before drilling, ensure the holes in your base match with the holes indicated on the template.

NOTE

3.The cable can either be routed through a 3/4” (19 mm) diameter hole directly under the mounting base or through the cutout in the back of the base (see Figure 2-14).

4.Drill the mounting screw holes using a drill bit of the appropriate diameter for your mounting screws or bolts.

5.Drill the cable routing hole using a 3/4” (19 mm) drill bit (optional).

It may be necessary to shorten the stalk that supports the display head so that the display is installed at eye level.

Product Reference Guide