2.If the top edge of the platter is blocked, you may find it easier to grasp the platter vertical bezel as shown in Figure 3-3b.

 

Use caution to avoid damage to the now exposed horizontal and vertical

 

scan windows. If cleaning of these windows is necessary, use a nonabrasive,

 

mild, water-based glass cleaner and paper towels or lint-free cleaning tis-

NOTE

sues and take care to avoid scratching these windows (damage to the win-

dows can degrade scanning performance).

3.The vertical scan window is held in place by two tabs each on its top and bottom edges. To remove it, carefully push out on the top as shown in Figure 3-4and lift it out. Carefully dispose of any damaged glass.

Figure 3-4. Vertical Scan Window Removal/Replacement

Vertical Scan Window

3-12