Scale Zero Push ButtonThe Scale Zero Push Button is used for multiple functions as listed inTable A-3.The Scale Zero Push Button has no function in a “scanner only” model.

NOTE

Table A-3. Scale Zero Push Button Functions

PRESS

FUNCTION

COMMENT

DURATION

 

 

 

 

 

 

 

 

 

 

When programmed to do so, the yellow LED should be lit when no

MomentaryZero Scale

weight is on the scale, indicating scale at zero. If it is not, press the

switch to zero the scale. The unit will sound a “click” upon pressing

 

 

 

 

the button.

 

 

 

 

Scale Diagnostics

This mode allows system support personnel to troubleshoot prob-

4 Seconds

lems with the scale. Momentarily press the Scale Zero Push Button

Modea

 

or cycle power to exit Scale Diagnostics Mode.

 

 

 

 

 

a. Diagnostics Mode is meant for use by trained systems support personnel. Users should not need to initi ate this function under normal circumstances.

Calibration Switch

This switch initiates the scale’s calibration routine. A certified weight set is needed to perform the scale calibration steps detailed in Section 5, Calibration . This switch is not included in scanners without scale modules.

Calibration Switch Seal

This seal allows you to secure the Calibration Switch access cover and restrict access to the Calibration Switch. If the calibration seal is broken or missing, you may be prohibited from operating the scale without recertifi- cation. Check local and state requirements for specific restrictions.

Product Reference Guide