Indicator LEDs

The green LED indicates scanner status, and the yellow LED is primarily used to show scale status as described in Table A-1below:

Table A-1. Green and Yellow LED Functions
LED

 

 

DURATIONCOMMENT
INDICATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Scale at ZeroaYellow LED on steadyThe scale is at rest and reads zero weight.

 

 

 

 

 

 

 

 

 

 

 

 

Scanner Activea

Green LED on steady and dim

The scanner is ready for operation. Scanning is

 

 

 

 

 

immediately available.

 

 

 

 

 

 

 

 

 

 

 

 

 

Good ReadGreen LED - bright flash

Indicates a bar code has been read and decoded.

Indicationa

 

 

 

 

 

 

 

 

 

 

 

Program ModeGreen LED - Continuous flashing

Indicates the scanner is in Label Programming

Indication

 

 

 

 

 

Mode. Cycle power to exit Programming Mode.

 

 

 

 

 

 

 

Sleep Mode

Green LED blinks at a 2-second rate

The scanner motor and/or laser have automati-

cally switched off and the unit has entered Sleep

Indication

 

 

 

 

 

 

 

 

 

 

Mode due to extended inactivity.

 

 

 

 

 

 

 

 

 

 

 

 

 

Host Disabled1-second off, 1/10-second onHost has disabled scanning.

 

 

 

 

 

 

 

 

 

 

 

 

 

Audible low tone 3 seconds.

Serves notice that a fatal FRU failure has been

Field Replace-

detected. Consult Error Codes in Section 4 for

Alternating Green/Yellow LED flashes

able Unit (FRU)

more details. If a low tone is heard, but continuous

continuously.
Warning (Error

flashing is not observed, the scanner can still func-

 

 

 

 

 

Mode)

 

 

 

 

 

tion in a limited capacity. Call systems support for

 

 

 

 

 

 

 

 

 

 

 

service in either case.

 

 

 

 

 

 

 

 

Green LED flashes a coded

Occurs ONLY upon Volume/Tone button push fol-

 

sequence in concert with the speaker.

FRU Indication

lowing a FRU warning. Enables service techni-

 

 

 

 

 

 

 

 

 

 

 

cians to identify FRU failures.

 

 

 

 

 

 

 

 

 

 

 

 

 

a. Certain functions of the Green and Yellow LEDs are selectable to be enabled or disabled. Your scanner may not be programmed to display all indications.

A-2

Magellan® 8500 Scanner