About Your System 23
POST Error Codes

Collecting System Event Log for Investigation

Error Messages are logged in the System Event Log (SEL). The SEL can be

accessed through system BIOS and the BMC setup for investigation. You can

also access SEL by browsing to the IP address of the BMC.

Code Log in BMC Cause Corrective Actions
0000h Yes Timer Count Read/Write Error Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page143.
0003h Yes CMOS Battery Error See "Troubleshooting the
System Battery" on
page118.
0004h Yes CMOS Diagnostic Status Error Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page143.
0005h Yes CMOS Checksum Error Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page143.
000Bh Yes CMOS Memory Size Error Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists, see
"Getting Help" on page143.