Code

Log in BMC

Cause

Corrective Actions

 

 

 

 

000Ch

Yes

RAM Read/Write Test Error

Remove AC power to the

 

 

 

system for 10 seconds and

 

 

 

restart the system.

 

 

 

If the problem persists, see

 

 

 

"Getting Help" on page 143.

 

 

 

 

0012h

Yes

CMOS Date Time Error

See "Troubleshooting the

 

 

 

System Battery" on

 

 

 

page 118.

 

 

 

If the problem persists, see

 

 

 

"Getting Help" on page 143.

 

 

 

 

0040h

Yes

Refresh Timer Error

Remove AC power to the

 

 

 

system for 10 seconds and

 

 

 

restart the system.

 

 

 

If the problem persists, see

 

 

 

"Getting Help" on page 143.

 

 

 

 

0041h

Yes

Display Memory Error

Remove AC power to the

 

 

 

system for 10 seconds and

 

 

 

restart the system.

 

 

 

If the problem persists, see

 

 

 

"Getting Help" on page 143.

 

 

 

 

0044h

Yes

DMAC Controller Error

See "Troubleshooting

 

 

 

System Memory" on

 

 

 

page 121.

 

 

 

If the problem persists, see

 

 

 

"Getting Help" on page 143.

 

 

 

 

0045h

Yes

DMAC1 Channel Register Error

See "Troubleshooting

 

 

 

System Memory" on

 

 

 

page 121.

 

 

 

If the problem persists, see

 

 

 

"Getting Help" on page 143.

 

 

 

 

0046h

Yes

DMAC2 Channel Register Error

See "Troubleshooting

 

 

 

System Memory" on

 

 

 

page 121.

If the problem persists, see "Getting Help" on page 143.

24

About Your System

Page 24
Image 24
Dell C6100 owner manual 000Ch Yes