Selecting the Rear Panel Remote Port Protocol and Baud Rate

All switchers can operate at the 9600, 19200, 38400, and 115200 baud rate. Switchers other than the MTPX Plus 128 can support either RS-232 or RS-422 serial communication protocol. The settings of these variables can be viewed and changed from the front panel.

View and configure the serial communications settings as follows:

1.Select Serial Port and Audio/RS-232 Input Configuration mode: Simultaneously press and hold all Control buttons (Enter, Preset, View, and Esc).

Press and hold the buttons.

C O N T R O L

ENTER

PRESET

VIEW

ESC

 

 

 

C O N T R O L

 

2 seconds

 

VIEW

ESC

ENTER

PRESET

 

 

I / O

VIDEO

AUDIO

NOTES: The Input buttons indicate the configuration of the secondary wire pairs. See

Selecting the TP wire pair secondary input”,

earlier in this section.

The MTPX Plus 128 is RS-232 only. For this switcher, the Video and Audio button indications have no meaning.

All Control buttons light with

Both I/O buttons light

one flashing.

with one flashing.

The flashing Control button indicates the baud rate as follows:

Enter — 9600

Preset — 19200

View — 38400

Esc — 115200

The flashing I/O button indicates the protocol as follows:

Video — RS-232

Audio — RS-422/RS-485

In this example, the port is set to RS-232 at 9600 baud.

2.Release the Control buttons.

NOTE: If front panel Lock mode 2 is selected and you try to perform step 3, the

actions are ignored and the Enter, Video, and Audio buttons flash (see

Setting the Front Panel Locks (Executive Modes)” on page 59).

3.Change a value: Press and release the button that relates to the desired value.

Press and release the button(s) to configure the port as

follows:

 

Baud rate:

 

Enter — 9600

Preset — 19200

View — 38400

Esc — 115200

Serial protocol:

 

Video — RS-232

Audio — RS-422/RS-485

The selected buttons blink and the others remain lit.

In this example, the port is set to RS-422 at 38400 baud.

C O N T R O L

ENTER

PRESET

VIEW

ESC

 

 

I / O

VIDEO

AUDIO

NOTE: The MTPX Plus 128 is RS-232 only. For this switcher, the Video and Audio button indications have no meaning.

4.Exit the Serial Port and Audio/RS-232 Input Configuration mode: Press and release an output button.

All Control, I/O, Input, and Output buttons

Press anreturn to unlit or background illumination. output button.

C O N T R O L

 

I / O

5

ENTER

PRESET

VIEW

ESC

VIDEO

AUDIO

 

 

 

 

 

 

MTPX Plus Series • Operation 63

Page 69
Image 69
Extron electronic 68-1383-01 REV. E manual Selecting the Rear Panel Remote Port Protocol and Baud Rate, Serial protocol