Setting up SMTP authorization

If desired, set the MTPX Plus to require SMTP authorization before accepting any e-mail as follows:

1.Click Edit. The button changes to Save.

2.Check the SMTP Authorization Required check box, located below the Domain Name field. This enables the User Name and Password fields below the check box.

3.Enter a user name and a password in the User Name and Password fields. For the MTPX Plus to accept their e-mail messages, senders must enter the user name and password.

NOTES: For the User name, any combination of letters, numerals, spaces, and

symbols except the comma (,) and the single and double quotation marks

(‘ and “) are valid. For the password, all characters except the comma are

valid. The user name and password can each be from 1 to 30 characters.

Both a user name and a password must be specified.

4.Click Save to save the user name and password.

Deselecting SMTP authorization

Remove SMTP authorization as follows:

1.Click Edit. The button changes to Save.

2.Click (deselect) the SMTP Authorization Required check box.

3.Click Save.

Domain Name field

The Domain Name field displays the domain name that the MTPX Plus switcher uses to log on to the e-mail server. Standard domain name conventions (for example: xxx.com) apply.

NOTE: The HTML language reserves certain characters for specific functions (see

Special Characters“ in the “Programming Guide” section). The @ character is acceptable only as the lead-in to the domain name (such as @folklore.net).

Email Address fields

The eight Email Address fields identify the e-mail addresses of the personnel to whom the MTPX Plus switcher e-mails notification of its failure and repair status. Standard e-mail address conventions (nnnnn@xxx.com) apply.

The Fans check boxes and drop boxes associated with each address field permit the operator to specify specific criteria under which the switcher will e-mail recipients. Check the Fans boxes to monitor the cooling. In the associated EMail Options drop box, select whether the recipient is to be e-mailed of failures, fixes, both, not notified, or to be removed from the e-mail list. The Suspend option is useful for temporarily removing personnel from the e-mail list when they are unavailable, such as on travel or vacation. Deleting an e-mail addressee and clicking the Save button removes the recipient from e-mail notification completely.

MTPX Plus Series • HTML Operation 134