Command/Response Table for SIS Commands (continued)

Command Function

SIS Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

 

 

 

 

 

 

 

 

Resets

 

 

 

Reset all input level and peaking adjustments

Reset all input and output skew adjustments

Reset global presets and names Reset one global preset Reset audio input levels

EZT}

Zpt]

EZK}

Zpk]

EZG}

Zpg]

EX2#ZG}

ZpgX2#]

EZA}

Zpa]

Clear all level and peaking adjustments to their default (0) values.

Clear all input and output skew values to 0 ns.

Clear all global presets and their names. Clear global preset X2#.

Reset all audio input levels (gain and attenuation) to 0 dB.

Reset audio output levels

Reset all mutes

Reset room map (outputs) Reset individual room

Reset all room presets and names Reset individual room preset and name Reset whole switcher

Absolute reset

EZV}

Zpv]

EZZ}

Zpz]

EZR}

Zpr]

EX2%ZR}

ZprX2%]

EZP}

Zpp]

EX2%*X2#ZP}

ZppX2%*X2#]

EZXXX}

Zpx]

EZQQQ}

Zpq]

Reset all audio output levels (volume) to 100% (no attenuation).

Reset all audio or RS-232 outputs to unmuted.

Clear all room definitions. Delete room X2%.

Clear an individual room preset and name. Clear an individual room preset and name.

Clear all ties and presets, reset all audio gains to 0 dB, and reset volume to 100%.

Similar to Reset whole switcher, plus clear the IP address to 192.168.254.254 and subnet mask to 255.255.000.000.

View ties, gain, volume, mutes, presets, and DIP switch status

Read RGB (video) output tie

X@&

X!]

Example:

5&

12]

Read video output tie

X@%

X!]

Example:

7%

02]

Read audio output tie

X@$

X!]

Example:

3$

06]

View output volume

X1*V

X1(]

Example:

7V

55]

View input gain

X*G

X2!]

Example:

4G

-02]

RGB input X! is tied to output X@.

Input 12 RGB is tied to output 5.

RGB input X! is tied to output X@. Input 2 video is tied to output 7. Audio input X! is tied to output X@. Input 6 audio is tied to output 3.

Volume for output 7 is 55%.

Audio input 3 level is -2 dB.

NOTE: X! = Input number

00

– (maximum number of inputs for your model)

X@ = Output number

01

– (maximum number of outputs for your model)

X* = Input number

01

– (maximum number of inputs for your model)

X1*

= Local audio output number

1

– 2

(MTPX Plus 128)

 

 

1

– 4

(matrix sizes 1616 and smaller)

 

 

1

– 8

(matrix sizes 1632 and larger)

X1( = Volume adjustment range

0

– 64 (1 dB/step except for 0-to-1, which is 22 dB)

X2! = Numeric dB value

–18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)

X2# = Global or room preset #

01

- 32 (global) or 01-10 (room)

X2% = Room # (for room presets)

10 max. (each can have up to 10 presets (X2#s) assigned

 

 

 

 

 

 

MTPX Plus Series • Programming Guide 88

Page 94
Image 94
Extron electronic 68-1383-01 REV. E manual Resets, Eza