Command Function

SIS Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

 

 

 

 

 

 

Information requests (continued)

 

 

Request system status

S

See below

 

MTPX Plus 128:

 

X3$•X3$•X3$•X3$•X3$•X3%•X3^•X3^•X3^]

Other matrix sizes 1616 and smaller:

X3$•X3$•X3$•X3$•X3$•X3%•X3^•X3^]

Matrix sizes 1632 and larger:

 

X3$•X3$•X3$•X3$•X3$•X3$•X3$•X3%•X3^•X3^•X3^]

Response description (MTPX Plus 128):

+3.3V+5V-5V+12V-12Vtemperature (degrees Fahrenheit)Fan 1 speedFan 2Fan 3] Response description (other matrix sizes 1616 and smaller):

+3.3V+5V-5V+12V-12Vtemperature (degrees Fahrenheit)Fan 1 speedFan 2] Response description (matrix sizes 1632 and larger):

+3.3V+5V-5V+12V-12V+2.5V-2.5Vtemperature (degrees Fahrenheit)Fan 1 speedFan 2Fan 3]

NOTE: Fans are numbered 1, 2, 3, from rear to front.

Example (MTPX Plus 128):

S

 

 

+12V power system at 11.52V

 

 

+3.28•+4.98•-5.01•+11.52•-12.35•+086.80•03590•03668•03668

 

+3.3V power system at 3.28V

Fan 1 (rear) rotating at 3590 RPM

NOTE: X3$ = Voltage

Positive or negative voltage and magnitude

 

X3% = Temperature

Degrees Fahrenheit

 

X3^ = Fan speed

RPM

 

MTPX Plus Series • Programming Guide 92