Command/Response Table for SIS Commands (continued)

Command Function

SIS Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

Audio input gain and attenuation

NOTE: The set gain (G) and set attenuation (g) commands are case sensitive.

Set audio input gain to +dB value Example:

Set audio input attenuation to -dB value

Increment gain

Example:

X!*X2)G

InX!•AudX2!]

 

1*2G

In1Aud+02]

Set input 1 audio gain to +2 dB.

X!*X2@g

InX!•AudX2!]

 

X!+G

InX!•AudX2!]

Increase gain by 1 dB.

5+G

In5Aud+03]

Increase audio input 5 level from +2 dB

 

 

to +3 dB.

Decrement gain

X!-G

InX!•AudX2!]

Decrease gain by 1 dB.

Example:

7-G

In7Aud-09]

Decrease audio input 7 level from -8

 

 

 

dB to -9 dB.

Read input gain

X!G

X2!]

 

Example:

3G

-06]

Audio input 3 level is at -6 dB.

Audio or RS-232 mute commands

Audio or RS-232 mute

X@*1Z

AmtX@*1]

Audio or RS-232 unmute

X@*0Z

AmtX@*0]

Read audio or RS-232 mute

X@Z

X1#]

Global audio or RS-232 mute

1*Z

Amt1]

Global audio or RS-232 unmute

0*Z

Amt0]

Mute output X@ audio or RS-232 (audio off).

Unmute output X@ audio or RS-232 (audio on).

1 = mute on, 0 = mute off.

Mute all audio or RS-232 outputs.

Unmute all audio or RS-232 outputs.

Names

NOTE: The HTML language reserves certain characters for specific functions (see “Special Characters“ on page 95).

Write global preset name

EX2#,X2$NG}

NmgX2#,X2$]

 

Example:

E1,Security 1NG}

Nmg01,Security 1]

Name global preset 1 “Security 1”.

Read global preset name

EX2#NG}

X2$]

 

Example:

E2NG}

Security 2]

 

Write room preset name

EX2%*X2#,X2$NP}

NmpX2%*X2#,X2$]

 

Example:

E1*3,Podium_DVDNP}

 

Name room 1, preset 3 “Podium_DVD”.

 

 

Nmp01*3,Podium_DVD]

 

Read room preset name

EX2%,X2#NP}

X2$]

 

NOTES: If a preset is unassigned, the X2$ displays [unassigned].

If a global preset is saved, but not yet named, the default name is Preset X2#.

If a room preset is saved, but not yet named, the default name is RmX2% PrstX2#.

NOTE: X! = Input number

01

– (maximum number of inputs for your model)

X@ = Output number

01

– (maximum number of outputs for your model)

X* = Input number

01

– (maximum number of inputs for your model)

X1# = Mute

0

= off

1 = on

X2)

= Audio gain

0

– 24 (1 dB/step)

 

X2! = Numeric dB value

–18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)

X2@ = Audio attenuation

1

– 18 (1 dB/step)

 

X2# = Global or room preset #

01

- 32, 10 maximum for a room preset

 

X2$ = Name

11 characters for room preset names

 

X2% = Room # (for room presets)

10 max. (each can have up to 10 presets (X2#s) assigned)

 

 

 

 

 

 