Table 7.

Reset Mode Comparison/Summary

 

Mode

Activation

 

Result

Purpose/Notes

1

Hold down the recessed Reset button

The switcher reverts to the factory default

Use mode 1 to revert

 

while applying power to the switcher.

firmware. Event scripting will not start if the

to the factory default

 

NOTE: After a mode 1 reset is

switcher is powered on in this mode. All user files

firmware version if

 

and settings (such as drivers, adjustments, and IP

incompatibility issues

 

performed, update the

settings) are maintained.

arise with user-loaded

 

switcher firmware to the

NOTE: If you do not want to update

firmware.

 

latest version. Do not

 

 

operate the switcher

firmware, or you performed a mode 1

 

 

firmware version that

reset by mistake, cycle power to the

 

 

results from the mode 1

switcher to return to the firmware

 

 

reset. If you want to

version that was running before

 

 

use the factory default

the mode 1 reset. Use the 0Q SIS

 

 

firmware, you must

command to confirm that the factory

 

 

upload that version

default firmware is no longer running

 

 

again (see the “Matrix

(look for the asterisk [*] following the

 

 

Software”section for

version number.

 

 

details on uploading

 

 

 

firmware).

 

 

 

3

Hold down the Reset button for about 3

Mode 3 turns events on or off. During resetting,

Mode 3 is useful for

 

seconds, until the Reset LED blinks once,

the Reset LED flashes 2 times if events are starting, 3

troubleshooting.

 

then press and release Reset (<1 second)

times if events are stopping.

 

 

within 1 second.

 

 

 

4

Hold down the Reset button for about

Mode 4:

Mode 4 enables you

 

6 seconds, until the Reset LED blinks

Enables ARP capability.

to set IP address

 

twice (once at 3 seconds and again at 6

Sets the IP address to the factory default.

information using ARP

 

seconds). Then press and release Reset

Sets the subnet address to the factory default.

and the MAC address.

 

(<1 second) within 1 second.

Sets the gateway address to the factory default.

 

Sets port mapping to the factory default.

Turns DHCP off.

Turn events off.

The Reset LED flashes four times in quick succession during the reset.

5

Hold down the Reset button for about

Mode 5 performs a complete reset to factory

Mode 5 is useful if

 

9 seconds, until the Reset LED blinks

defaults (with the exception of the firmware):

you want to start over

 

three times (once at 3 seconds, again

Does everything mode 4 does.

with configuration and

 

at 6 seconds, and then again at 9

Resets most all real time adjustments, including:

uploading or to replace

 

seconds). Then press and release Reset

clears all ties and presets,

events.

 

(<1 second) within 1 second.

clears all audio or RS-232 mutes,

 

 

NOTE: Mode 5 reset clears

clears all I/O grouping,

 

 

clears all input level/peaking,

 

 

most adjustments. To

clears all skew adjustments,

 

 

save these settings,

clears all output pre-peaking,

 

 

use the Windows-

disables all RS-232 output inserts,

 

 

based Matrix Switchers

sets all audio/RS-232 wire pairs to audio,

 

 

Control Program and the

clears all audio settings.

 

 

File > Save MATRIX

Resets all IP options.

 

 

settings as...

Removes/clears all files for the switcher.

 

 

selection before you

The reset LED flashes four times in quick succession

 

 

perform this reset (See

during the reset.

 

 

the “Matrix Software

 

 

 

section.

 

 

MTPX Plus Series • Operation 65

Page 71
Image 71
Extron electronic 68-1383-01 REV. E manual Reset Mode Comparison/Summary, Switcher reverts to the factory default