X6# = Verbose mode

0

= clear/none (default for Telnet connection)

 

1

= verbose mode (default for RS-232/RS-422 connection)

 

2

= tagged responses for queries

 

3

= verbose mode and tagged for queries

NOTE: If tagged responses is enabled (modes 2 and 3), all read commands return the constant string and the value as the set command does (for example, the read matrix name command ECN}, returns Ipn•X4)]).

X6$ =

Flow control

hardware, software, none (only the first letter required)

X6%

=

Data pacing (in ms between bytes)

0000 (default) - 1000

X6^ =

Time (in 10 ms increments) to wait for characters

10 (= 100 ms, default) - 32767

X6& =

Time (in 10 ms increments) to wait between characters

2

(= 20 ms, default) - 32767

X6*

=

Port timeout interval (in 10-sec. increments)

1

(= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)

Command/Response Table for IP-specific SIS Commands

Command Function

SIS Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

 

 

 

 

 

 

 

 

IP setup commands

 

 

 

Set matrix name

Read matrix name (location)

Reset matrix name to factory default Set time and date

Read time and date Set GMT offset

EX4)CN}

Ipn•X4)]

ECN}

X4)]

E•CN}

Ipn•X4)]

EX4@CT}

IptX4@]

ECT}

X4#]

EX4$CZ}

IpzX4$]

In the command, the divider between hours and minutes can be either a colon or a period. In the response, the divider is a colon.

Example:

Read GMT offset

Set Daylight Savings Time

Read Daylight Savings Time Set IP address

Read IP address

Read hardware address Read # of open connections Set subnet mask

Read subnet mask

Set gateway IP address Read gateway IP address Set administrator password Read administrator password

Reset (clear) administrator password Set user password

Read user password

Reset (clear) user password Set mail server, domainname Read mail server, domainname Set e-mail recipient

E8.3CZ}

Ipz+08:30]

ECZ}

X4$]

EX4%CX}

X4%]

ECX}

X4%]

EX4^CI}

IpiX4^]

ECI}

X4^]

ECH}

X4&]

ECC}

X4*]

EX4^CS}

IpsX4^]

ECS}

X4^]

EX4^CG}

IpgX4^]

ECG}

X4^]

EX4(CA}

Ipa•X4(]

ECA}

X4(]

E•CA}

Ipa•]

EX4(CU}

Ipu•X4(]

ECU}

X4(]

E•CU}

Ipu•]

EX4^,X5),X4(CM}

IpmX4^,X5),X4(]

ECM}

X4^,X5),X4(]

EX5!,X5@CR}

IprX5!,X5@,]

8.3 = 8:30

Reads MAC address.

This command sets the recipient. To receive e-mail notifications, you must then set the events that the switcher reports, using one or more separate Set e-mail events (EM) commands (see next page).

Example:

E72,Jsmith@folklore.netCR}

 

 

Ipr72,Jsmith@folklore.net,]

Read e-mail recipient

EX5!CR}

X5@,]

MTPX Plus Series • Programming Guide 94

Page 100
Image 100
Extron electronic 68-1383-01 REV. E manual Command/Response Table for IP-specific SIS Commands, IP setup commands