Remote Connection

Connect a host device, such as a computer, touch panel control, or RS-232 capable PDA to the switcher via the remote port of your switcher.

NOTE: The port can operate at 9600, 19200, 38400, or 115200 baud rates. Models other than the MTPX Plus 128 can support either the RS-232 or RS-422 serial

communication protocol (see “Selecting the Rear Panel Remote Port

Protocol and Baud Rate” in the “Operation” section to configure the Remote port from the front panel).

If desired, connect an MKP 2000 or MKP 3000 remote control panel to the Remote connector of the switcher. Refer to the MKP 2000 Remote Control Panel User Guide or the MKP 3000 Remote Control Panel User Guide for details.

iRemote (RS-232) connector (MTPX Plus 128) — A 3-pin captive screw connector for serial RS-232 control (see figure 11). Use the supplied tie-wrap to strap the serial cable to the extended tail of the connector.

RS-232

Tx Rx

Pin Function

TX Transmit data

RX Receive data

Gnd Signal ground

 

 

 

 

 

 

 

 

 

 

 

Controlling

Do not tin the wires!

Device

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bidirectional

 

 

 

 

 

Ground (

 

)

 

Ground (

 

 

 

)

 

 

 

 

 

 

 

Receive (Rx)

Receive (Rx)

Transmit (Tx)

Transmit (Tx)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: Cross the Tx and Rx lines once between the source and the target.

Figure 11. MTPX Plus 128 Remote Connector

CAUTION: The length of exposed wires is critical (see the CAUTIONS on page 14 for details).

NOTE: This port is hardwired for RS-232 only.

jRemote connector (all other models) — A 9-pin D connector for serial RS-232 or RS-422 control (see figure 12).

REMOTE

 

 

 

Pin RS-232 Function

RS-422 Function

 

 

 

1

Not used

Not used

 

 

RS232/RS422

2

TX

Transmit data

TX–

Transmit data (–)

1

6

3

RX

Receive data

RX–

Receive data (–)

 

 

 

4

Not used

Not used

 

 

 

5

9

 

5

Gnd

Signal ground

Gnd

Signal ground

 

6

Not used

Not used

 

 

 

 

 

7

Not used

RX+

Receive data (+)

 

 

 

8

Not used

TX+

Transmit data (+)

 

 

 

9

Not used

Not used

Figure 12. Remote Connector for all Other Models

See the “Programming Guide” section for definitions of the SIS commands (ASCII commands to control the switcher via this connector) and the “Matrix Software” section for details on how to install and use the control software.