X1%

=

TP output number

01 – (maximum number of TP outputs for your model)

X1^

=

Local video output number

1 or 2

NOTE: X1^ is applicable to MTPX Plus 128 and matrix sizes 1632 and larger only.

 

 

X1& = Local output sync polarity

0

= H- / V- (default)

3

= H+ / V+

 

1

= H+ / V-

4

= No sync processing (composite, S-video, YUV)

 

2

= H- / V+

 

 

X1*

= Local audio output number

1

– 2

(MTPX Plus 128)

 

 

 

1

– 4

(other matrix sizes 1616 and smaller)

 

 

 

1

– 8

(matrix sizes 1632 and larger)

X1( =

Volume adjustment range

0

– 64

(1 dB/step except for 0-to-1, which is 13 dB) (default = 64 [0 dB])

 

 

 

(See the table on page 84.)

X2)

=

Audio gain

0

– 24

(1 dB/step)

X2! =

Numeric dB value

–18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)

X2@ =

Audio attenuation

1

– 18

(1 dB/step)

X2# =

Global or room preset #

00 - 32 (global) or 00-10 (room) (0 = current configuration)

NOTE: A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is recalled from

memory, it becomes the current configuration.

X2$ = Name

12 characters maximum for input, output, and global preset names

 

11 characters maximum for room preset names

 

Upper- and lower-case alphanumeric characters and

 

_ / and spaces are valid.

NOTE: The HTML language reserves certain characters for specific functions (see “Special Characters“ on page 95).

X2% = Room # (for room presets)

10 max. (each can have up to 10 presets (X2#s) assigned)

NOTE: A Room is a subset of operator-selected outputs that relate to each other. The MTPX Plus switchers support up to 10 rooms, each of which can consist of from 1 to 16 outputs.

X2^ = Group # (for I/O grouping)

1 through 4 groups (0 = no group)

X2& = Audio or RS-232 mute:

0 = no mutes

2 = audio or RS-232 mute

X2*

=

Local input select DIP switch status

0 = RJ-45 position

1 = local input position

X2( = Number of inputs

8, 12, 16, or 32

 

X3)

= Number of outputs

8, 16, or 32

 

X3! = Part number

60-nnn-nn or 60-nnnn-nn

 

X3@ = Firmware version number to second decimal place (x.xx)

 

 

X3# =

Verbose firmware version-description-upload date/time (see the Query firmware version (verbose) command on page 91).

X3$ =

Voltage

Positive or negative voltage and magnitude

X3%

=

Internal temperature

Degrees Fahrenheit

 

X3^ = Fan speed

RPM

 

MTPX Plus Series • Programming Guide 79

Page 85
Image 85
Extron electronic 68-1383-01 REV. E manual X1 =