Command/Response Table for SIS Commands (continued)

Command Function

SIS Command

Response

Additional description

 

(Host to Unit)

(Unit to Host)

 

Input skew adjustment

NOTE: For the MTPX Plus 128, these commands are valid for inputs 5 through 12 only.

Set all input skew adjustment values

EX#*X1)*X1)*X1)Iseq}

 

 

 

IseqX#*X1)*X1)*X1)]

Example:

E2*0*0*4Iseq}

Iseq02*00*00*04]

Increment one input skew

EX#*X1!+Iseq}

IseqX#*X1)*X1)*X1)]

adjustment value

 

 

Example:

E2*2+Iseq}

Iseq02*00*00*05]

Set a specific skew adjustment for the TP input. X1) values are listed in RGB order.

Set skew settings for input 2 as follows: Red = 0 ns

Green = 0 ns

Blue = 8 ns (delayed 8 ns).

Increase the X1! plane skew adjustment for input X# by 1 step (2 ns).

Increase the blue skew for input 2 by 2 ns to 10 ns.

Decrement one input skew

EX#*X1!-Iseq}

IseqX#*X1)*X1)*X1)]

Decrease the X1! plane skew adjustment

adjustment value

 

 

for input X# by 1 step (2 ns).

Read input skew adjustment values

EX#Iseq}

X1)*X1)*X1)]

 

EDID commands

NOTE: For the MTPX Plus 128, these commands are valid for inputs 1 through 4 only.

Assign EDID data to an input Assign EDID data to all inputs

Save output #1 EDID data to a user- defined space

View EDID data assigment

EAX**X1$EDID}

EdidAX**X1$]

EA*X1$*EDID}

EdidA0*X1$]

ES*X1$EDID}

EdidSX1$]

EA*X*EDID}

X1$]

For this command, the X1$ value must be from 31 to 34.

Output pre-peaking

Set output pre-peaking on

EX1@*1Opek}

OpekX1@*1]

Pre-peak the TP output.

Set output pre-peaking off

EX1@*0Opek}

OpekX1@*0]

Do not pre-peak the TP output.

Read output pre-peaking setting

EX1@Opek}

X1#]

 

NOTE: X# = TP input number

01

– (maximum number of TP inputs for your model)

X* = Input number

01

– (maximum number of inputs for your model)

X1) = Skew adjustment range

00

– 31 (each step = 2 ns)

 

X1! = Video plane

0

= red

 

 

1

= green

 

 

2

= blue

 

X1@ = Pre-peakable output number

MTPX Plus 168

01 – 04

 

MTPX Plus 128, 816, 1616, 3216

01 – 08

 

MTPX Plus 1632, 3232

01 – 16

X1# = Pre-peaking

0

= off

 

 

1

= on

 

X1$ = DDC value (EDID)

See page 78.

 

 

 

 

 

 