ASCII to Hex Conversion Table

Using the Command and Response Tables

The command and response

Space

table begins on page 80.

Symbols used in the

 

table represent variables in the

 

command and response fields.

 

Command and response examples

are shown throughout the table.

With the exception of the audio

input gain and attenuation

 

commands, the SIS commands are

not case sensitive. The ASCII to

 

HEX conversion table at right is for

use with the command and response table.

Symbol definitions

]= Carriage return/line feed

} = Carriage return (no line feed)

= Pipe (can be used interchangeably with the } character)

• = space E = Escape key

W = Can be used interchangeable with the E character X! = Input number (for tie)

X@ = Output number X# = TP input number

X$ = Audio/RS-232 wire pair input type X% = RS-232 output insert port

X^

=

RS-232 output insert status

X&

=

Input signal level/peaking range

X*

= Input number

X(

=

Threshold

X1)

= Skew adjustment range

X1!

= Video plane

X1@

= Pre-peakable output number

X1#

= Mute, pre-peaking, Lock mode, power supply

X1$

= DDC value (EDID):

00 – (maximum number of inputs for your model) (00 = untied)

01 – (maximum number of outputs for your model)

01– (maximum number of TP inputs for your model)

0

= audio

1

= RS-232

MTPX Plus 128, 168, 816, 1616

01 – 08

MTPX Plus 1632, 3216, 3232

01 – 16

0

= disabled

1

= enabled

000 – 255

01 – (maximum number of inputs for your model)

0 = outside of threshold

1 = within threshold

00

– 31 (each step = 2ns)

 

 

0 = red

2 = blue

1 = green

 

 

MTPX Plus 168

01

– 04

MTPX Plus 128, 816, 1616, 3216

01

– 08

MTPX Plus 1632, 3232

01

– 16

0 = off/mode 0/not OK

2 = mode 2

1 = on/mode 1/OK

 

 

00

= Automatic

18

= 1366 x 768 @ 60 Hz

01

= Output 1

19

= 1400 x 1050 @ 50 Hz

02

= Output 2

20

= 1400 x 1050 @ 60 Hz

03

= 800 x 600 @ 50Hz

21

= 1440 X 900 @ 50 Hz

04

= 800 x 600 @ 60 Hz

22

= 1440 x 900 @ 60 Hz

05

= 1024 x 768 @ 50 Hz

23

= 1600 x 1200 @ 50 Hz

06

= 1024 x 768 @ 60 Hz

24

= 1600 x 1200 @ 60 Hz

07

= 1280 x 720 @ 50 Hz

25

= 1680 x 1050 @ 50 Hz

08

= 1280 x 720 @ 60 Hz

26

= 1680 x 1050 @ 60 Hz

09

= 1280 x 768 @ 50 Hz

27

= 1920 x 1080 @ 50 Hz

10

= 1280 x 768 @ 60 Hz

28

= 1920 x 1080 @ 60 Hz

11

= 1280 x 800 @ 50 Hz

29

= 1920 x 1200 @ 50 Hz

12

= 1280 x 800 @ 60 Hz

30

= 1920 x 1200 @ 60 Hz

13

= 1280 x 1024 @ 50 Hz

31

= User defined

14

= 1280 x 1024 @ 60 Hz

32

= User defined

15

= 1360 x 768 @ 50 Hz

33

= User defined

16

= 1360 x 768 @ 60 Hz

34

= User defined

17

= 1366 x 768 @ 50 Hz

 

 

MTPX Plus Series • Programming Guide 78

Page 84