Connectors

Connector

CAT 6 jack (black), qty. 10

CAT 6 jack (red), qty. 10

CAT 6 jack (blue), qty. 10

CAT 6 jack (orange), qty. 10

CAT 6 jack (gray), qty. 10

CAT 6 jack (white), qty. 10

CAT 6 jack (ivory), qty. 10

Part Number

100-476-01

100-477-01

100-478-01

100-479-01

100-480-01

100-481-01

100-482-01

Mounting the Switcher

The MTPX Plus switchers are housed in a 1U high (MTPX Plus 128), 2U high

(other matrix sizes 1616 and smaller), or 3U high (matrix sizes 1632 and larger) metal enclosures. The 1U enclosure is rack mountable using the provided MBD 149 Through-desk and rack mouting kit (part number 70-077-03). The 2U and 3U enclosures are mountable without extra hardware.

Tabletop Use

For tabletop use, affix one of the supplied self-adhesive rubber feet to each corner of the bottom of the switcher.

UL Rack-Mounting Guidelines

The following Underwriters Laboratories (UL) requirements pertain to the installation of the matrix switcher into a wall or furniture.

1.Elevated operating ambient temperature — If installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consider installing the equipment in an environment compatible with the maximum ambient temperature (Tma = +122 °F, +50 °C) specified by Extron.

2.Reduced air flow — Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised.

3.Mechanical loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.

4.Circuit overloading — Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

5.Reliable earthing (grounding) — Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (such as use of power strips).

MTPX Plus Series • Reference Information 159

Page 165
Image 165