Number of Connections

An MTPX Plus switcher can have up to 200 simultaneous TCP connections, including all http sockets and telnet connections. When the connection limit is reached, the switcher accepts no new connections until some have been closed. No error message or indication is given that the connection limit has been reached. To maximize performance of an IP Link device, the number of connections should stay low and unnecessary open sockets should be closed.

Using Verbose Mode

Telnet connections to an MTPX Plus switcher can be used to monitor for changes that occur on the switcher, such as front panel operations and SIS commands from other telnet sockets or a serial port. For a telnet session to receive change notices from the switcher, the telnet session must be in verbose mode 1 or 3. See the Verbose Mode SIS command on page 95. In verbose mode 3, the telnet socket reports changes in messages that resemble SIS command responses.

Host-to-Switcher Instructions

The switcher accepts SIS (Simple Instruction Set) commands through the RS-232 port. SIS commands consist of one or more characters per command field. They do not require any special characters to begin or end the command character sequence. Each switcher response to an SIS command ends with a carriage return and a line feed (CR/LF = ]), which signals the end of the response character string. A string is one or more characters.

Switcher-initiated Messages

When a local event such as a front panel operation or an IR 501 command string occurs, the switcher responds by sending a message to the host. The switcher-initiated messages are listed below (underlined).

The switcher does not expect a response from the host, but, for example, the host program might request a new status.

(C)COPYRIGHT 20yy, Extron Electronics MTPX, Vx.xx, 60-nnn-01 {day,date, time}]

The switcher initiates the copyright message when it is first powered on or when a connection via Internet protocol (IP) is established. Vx.xx is the firmware version number and 60-nnnn-01 is the switcher part number.

NOTE: {Day, date, time} are only reported if the connection is via the LAN port.

Password:]

The switcher initiates the password message immediately after the copyright message when the controlling system is connected using TCP/IP or Telnet and the switcher is password protected. This message means that the switcher requires an administrator or user level password before it will perform the commands entered via this link. The switcher repeats the password message response for every entry other than a valid password until a valid password is entered.

]Login Administrator]

]Login User]

The switcher initiates the login message when a correct administrator or user password has been entered. If the user and administrator passwords are the same, the switcher defaults to administrator privileges.

MTPX Plus Series • Programming Guide 76

Page 82
Image 82
Extron electronic 68-1383-01 REV. E Host-to-Switcher Instructions, Switcher-initiated Messages, Number of Connections