Remote Port
CRemote
9 ![]()
REMOTE 422- ![]()
5
1
Pin |
| Function |
| Function |
1 | — | Not used | — | Not used |
2 | Tx | Transmit data | Tx– | Transmit data |
3 | Rx | Receive data | Rx– | Receive data |
4 | — | Not used | — | Not used |
5 | Gnd | Signal ground | Gnd | Signal ground |
6 | — | Not used | — | Not used |
7 | — | Not used | Rx+ | Receive data (+) |
8 | — | Not used | Tx+ | Transmit data (+) |
9 | — | Not used | — | Not used |
Figure 9. Remote RS-232/RS-422 Connector
See Programming Guide on page 52 for definitions of the SIS commands (serial commands to control the switcher via this connector) and Matrix Software on page 71 for details on how to install and use the control software.
NOTE: The switcher can support either the
See the Command and Response Table for IP- and
If desired, connect an MKP 2000 or MKP 3000 remote control panel to the Remote
Ethernet Connection
DLAN port (see figure 3 and figure 4) — For IP control of the system, connect the matrix switcher to a PC or to an Ethernet LAN via this
from anywhere in the world. You can also control the switcher from a PC that is running the Extron Matrix Switchers Control Program or has downloaded HTML pages from the switcher.
Link LED indicator — The green (link) LED indicates that the switcher is properly connected to an Ethernet LAN. This LED should light steadily.
Act LED indicator — The yellow (activity) LED indicates transmission of data packets on the
Cabling
It is vital that your Ethernet cables be the correct cable type and that they be properly terminated with the correct pinout. Ethernet links use Category (CAT) 3, 5e, or CAT 6, unshielded twisted pair (UTP) or shielded twisted pair (STP) cables, terminated with
NOTES:
•Do not use standard telephone cables. Telephone cables do not support Ethernet or Fast Ethernet.
•Do not stretch or bend cables. Transmission errors can occur.
FOX Matrix 3200 and 7200 Switchers • Installation 13