Suggested applications for the I/O grouping feature include:

Segregating sync-critical inputs and outputs

Segregating specific video formats to prevent an input in one video format from being inadvertently applied to an output device that supports another video format

Segregating input and output devices that are in separate rooms

Segregating incompatible fiber signals, such as those from a FOX 500 system and those from a FOX HD-SDI system

Isolating video from being displayed on specific output devices for operational security reasons

The I/O groups can be set up on the front panel or by using the Remote port, Configuration port, or LAN ports and either the SIS (see the Programming Guide section, beginning on page 52 ) or the Matrix Switchers Control Program (see the Matrix Software section, beginning on page 71).

Create I/O groups on the front panel as follows:

NOTE: I/O groups are protected when front panel Lock mode 2 is selected. You can view the groups in Lock mode 2, but you cannot change them from the front panel (see Locking the Front Panel (Executive Mode) on page 41).

1.Press the Esc button to clear any front panel button indications that may be lit.

2.To enter I/O Group mode, press and hold the Input 1 and Output 1 buttons until the input and output buttons light to display the ungrouped inputs and outputs.

3.Press and release one of the Control buttons to select a group:

Press the Enter button to select group 1.

 

 

 

 

 

 

 

 

 

 

C O N T R O L

 

 

Press the Preset button to select group 2.

 

 

 

 

 

 

 

 

 

ENTER

PRESET

VIEW

ESC

 

Press the View button to select group 3.

 

 

 

 

 

 

 

Group # 1

2

3

4

 

 

 

 

Press the Esc button to select group 4.

4.Select the one or more inputs and one or more outputs to assign to the group by pressing the input and output buttons.

5.Allow the I/O Group mode to time out after approximately 30 seconds.

NOTES:

Ties between groups (an input in group 1 tied to an output in group 2) can be created under serial port or Ethernet control.

Ties that were created before I/O groups were created remain valid, even if they include inputs and outputs in different groups.

Presets can be created under serial port or Ethernet control that tie inputs and outputs across group boundaries. These presets are selectable from the front panel.

An input or output can be assigned to only one group. If you assign an input or output to a group and that input or output is already assigned to a different group, the older grouping is disboarded in favor of the new grouping.

For I/O groups to have any function, at least two groups must be created.

FOX Matrix 3200 and 7200 Switchers • Operation 34

Page 42
Image 42
Extron electronic 7200, 3200 manual Press the Enter button to select group, Press the Preset button to select group