If desired, adjust any of these values as follows:

1.Click in the desired field. The field changes to an editable field appropriate to the value being changed and the graphic cursor becomes a text cursor.

The Date field becomes a set date field, with the date in the format (M)M/(D)D/YYYY. Leading zeroes are not shown.

The Time (local) field becomes a set time field, with the time in the format HH:MM:SS (00:00:00 to 23:59:59).

The GMT field becomes a set offset field, with the offset in the format ±HH:MM (–12:00 to +14:00).

2.Edit the field as desired to set the proper value. For time, remember to use 24-hour time. Leading zeroes are optional.

3.Press the <Tab> key on the keyboard or click in another field to exit the set date field.

4.Click the Take button to make the date change take affect.

Sync Time to PC button

Clicking the Sync Time to PC button causes the computer you are operating to send its internal time to the switcher in a set time command.

Use Daylight Saving check box

To turn Daylight Saving Time on and off for North America, select the Use Daylight Saving check box. When Daylight Saving Time is turned on, the switcher automatically updates its internal clock between Standard Time and Daylight Saving Time in the spring and fall on the date that the time change occurs in North America. When Daylight Saving Time is turned off, the switcher does not adjust its time reference.

NOTE: For Daylight Saving Time in Europe and Brazil, see the Set Daylight Saving Time SIS command on page 68.

Administrator Password and User Password fields

The Administrator Password field displays the password required to log on to the matrix switcher via the Ethernet port with all of the rights and privileges of the administrator. The User Password field displays the password required to log on to the matrix switcher via the Ethernet port as a user, without all of the rights and privileges of the administrator. Passwords are case sensitive and are limited to 12 upper-case and lower-case alphanumeric characters.

Both password fields are masked with asterisks (************) as a security measure.

NOTES:

Editing the Administrator Password field while connected via the Ethernet port can immediately disconnect the user from the switcher. Extron recommends editing this field using either serial port and protecting the Ethernet access to this screen by assigning an administrator password to qualified and knowledgeable personnel only.

An administrator password must be created before a user password can be created.

The HTML language reserves certain characters for specific functions (see Special Characters on page 70).

FOX Matrix 3200 and 7200 Switchers • Matrix Software 78