Extron
VSC 900D | VGA Input |
| Extron | |
Extron | FOX Matrix 3200 | |
Matrix Switcher | ||
BBG 6 A | ||
| ||
Blackburst/Color Bars/ | ||
Audio Generator |
| |
| |
| |
| |
| |
REMOTE | RESET |
LAN ACT LINK |
Video Camera | Video Camera | Video Camera |
Figure 12. Multiple Device Example of a FOX Matrix 3200 External Sync
Power Supply Modules and Indicator LEDs
GPrimary and Redundant AC power connectors (see figure 3 on page 8 and figure 4 on page 9) — Plug standard IEC power cords into these connectors to connect the switcher to 100 VAC to 240 VAC, 50 or 60 Hz power sources.
NOTE: For the most reliable power, connect the power cord from the Redundant power connector to either an uninterruptible power source or to a power source that is completely independent from the primary power source.
HPrimary and Redundant power supply indicator LEDs (see figure 3 and figure 4) —
Green — Indicates that the associated power supply is operating within normal tolerances.
Red — Indicates that the associated power supply is operating outside the normal tolerances or has failed. See Removing and Installing a Power Supply Module on page 113 section to replace the power supply.
Cooling Fan assemblies
IPrimary and Redundant cooling fans (see figure 3 and figure 4) — Cool the equipment. If a fan has failed, replace it at your earliest opportunity. See Removing and Installing a Fan Module on page 114 to replace the fans.